Page 14
Important:
Follow Step 10 – 11 only if you have GAC (hard plastic carbon filter.) If carbon particles are
not rinsed out they may clog the flow restrictor which could then foul the membrane. The carbon block
filter does not need to be flushed.
Perform steps 4, 5 and 6 in the start up instruction section.
Hold green tube over a bucket. Turn on incoming water at Adapta
Valve and flush out all carbon particles from the filters. As soon as the
water runs clear, turn off the incoming water and re-attach green tube to
the Automatic Shut-Off Valve. Using a 5/8" wrench tighten black nut
securely.
After changing pre-filters, disconnect the green tube at the Automatic
Shut-Off Valve, using a 5/8" wrench to loosen nut.
Step 9
Step 10
Step 11
Annual Maintenance
Watts Premier sells a filter change kit which includes pre-filters, orings, a final filter, connectors, and a
wrench. Call 1-800-752-5582 or buy online at www.wattspremier.com.
Perform 6 month system mainenance. (previous section)
The Final Filter should be replaced annually. Remove White Nuts at
both ends of the filter to replace the old Final Filter. Replace with new
filter and connectors.
Annual Sanitizing of unit is recommended to prevent bacteria growth.
Remove the Blue Tube from the left side of the Automatic Shut Off
Valve (Marked “OUT”).
Using a clean eye dropper insert ½ teaspoon of 3% hydrogen peroxide
or common household beach into the blue tube. This will flow into the
tank once water is turned back on to unit. Reattach blue tube to
Automatic Shut Off Valve. Follow start up procedure.
Step 1
Step 2
Step 4
Step 5
Note:
Flow Arrow on final filter must be pointing in the direction of the out flow
of water.