41
The selection or switching between them can be done via mobile application remotely or
manually directly from the Thermic or the GATE.
The different operating modes are explained in detail:
OFF
The heater remains off. However, the room temperature is visible and the average values of the
temperature will be registered every 15 minutes to be accessible on the mobile app.
MANUAL
This operating mode works when the user manually sets the target temperature, either with the
wheel or with the mobile application. This means that the Thermic will regulate the heater so
that the temperature will be slightly higher or equal to the target one. As in the OFF mode, the
user will have visible the current temperature and the average values will be registered as well
every 15 minutes.
AUTO
This operation mode works when the user programs a schedule. The user will set up a calendar
with the wanted temperature values and the Thermic will perform them automatically. This
performance will be explained in detail further forward.
AUTO-MANUAL
The AUTO-MANUAL mode activates automatically when the target temperature is changed
(auctioning the temperature wheel or from the apps) when the Thermic is in AUTO mode. The
AUTO-MANUAL mode allows changing temporarily the target temperature of the Thermic
established by the calendar programmed on AUTO mode, allowing that the Thermic recovers
the AUTO mode and the set up calendar when finalizing the AUTO-MANUAL mode.
The Thermic’s LCD will show both the AUTO and the MANUAL symbols at the same time to show
that the AUTO-MANUAL is active. On the mobile app it will show AUTO+MANUAL symbols
highlighted.
The AUTO-MANUAL mode ends up automatically in the following target-temperature change
set up in the calendar, getting the AUTO mode back. In order to end up the target-temperature
variation over the established calendar manually, press once the mode-change-button or chose
the AUTO mode from the apps.