A
A
A-1
APPENDIX A: TECHNICAL SPECIFICATIONS
007S
015S
022S
007T
015T
022T
037T
0.75
1.5
2.2
0.75
1.5
2.2
3.7
1
2
3
1
2
3
5
1.9
2.5
4.2
2.3
3.2
4.2
6.5
5.0
7.0
11.0
2.7
4.2
5.5
8.5
Recommended
50 Hz
81N4/91S4
91L4
101L4
81N4/91S4
91L4
101L4
114M4
WATT motor *)
87/100Hz
81K4
81N4
91S4
101L4
11.9/ 7.0
15.3/ 7.6
22/15.5
3.2
4.3
5.9
11.2
Keypad
External
Signal
Keypad
External
Signal
Fan-cooled
W
118
118
150
118
118
118
150
Dimensions (mm)
H
185
185
260
185
185
185
260
D
160
160
160
145
160
145
160
V2500-0wxyz_W1
size
B
B
D
A
B
C
D
Weight
kg
2.7
3.2
4.5
2.7
3.2
3.2
3
EMC-conformity
cable len.(2nd env.)
m
65
65
65
60
60
60
60
cable len.(1st env.)
m
35
35
35
15
15
15
15
*) 4-pole motor - for details on motor type and data please refer to the current motor catalogue EUSAS'03
Vibration
Enviromental Conditions
Installation Location
Pollution Degree
Ambient Temperature
Other Functions
Options
Storage/ Transportation Temp.
Ambient Humidity
Protection
Cooling Methods
V/F Pattern
Stall Prevention Level
Operating Characteristics
Frequency Setting
Operation Setting
Signal
Multi-Function Input Signal
Multi-Function Output Indication
Analog Output Signal
AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, Local/Remote indication,
PLC Operation indication and Auxiliary Motor Output
1/3-phase 180...264 Vac
Frequency Tolerance
47 – 63 Hz
Control
Characteristics
Control System
Output Frequency Resolution
Torque Characteristics
Overload Endurance
Accel/Decel Time
SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 1-15kHz)
Rated Output Capacity (kVA)
Rated Output Current (A)
Maximum Output Voltage (V)
Input Rating
Rated Input Current (A)
Rated Voltage
EMC
400/460V class
Proportional to Input Voltage
3-phase 342...528 Vac
Voltage Class
230V Class
OPTI-line V2500-0
_ _ _ _
yW1
Max. Applicable Motor Output (kW)
Max. Applicable Motor Output (HP)
Output Rati
ng
Adjustable V/F pattern (for different types load)
0.1 to 3600 seconds (4 Independent settings for Accel/Decel Time)
Below 90% RH (non-condensing)
9.80665m/s
2
(1G) less than 20Hz, 5.88m/s
2
(0.6G) at 20 to 50Hz
Convection cooled
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
2
-10
o
C to 40
o
C (-10
o
C to 50
o
C without blind plate) Non-Condensing and not frozen
-20
o
C to 60
o
C
Potentiometer-5K
Ω
/0.5W, DC 0 to +10V or -10 to +10V (Input impedance 47K
Ω
), RS-485 interface,
4 to 20mA (Input impedance 250
Ω
), Multi-Function Inputs 1 to 6 (16 steps, Jog, up/down)
Setting by
!
"
optional external EMC-filter according to EN61800-3 amendment A11
20 to 250%, Setting of Rated Current
Convection cooled
Fan-cooled
Including auto-torque boost & auto-slip compensation; starting torque up to 150% at 1.0Hz
0.01Hz
Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating, External Fault, Electronic
thermal, Ground Fault.
Filter, Braking Resistor, internal PG-Feedback for closed loop Vector Control, Communication Modules for
DeviceNet and ProfiBus DP (coming soon).
AVR, S-Curve, Over-Voltage, Over-Current Stall Prevention, Fault Records, Adjustable Carrier Frequency, DC
Braking, Braking Chopper, Momentary Power Loss restart, Auto Tuning, Frequency Limits, Parameter
Lock/Reset, new Sensorless Vector Control, Counter, PID Control, Fan & Pump Control, PLC, MODBUS
Communication, Reverse Inhibition
Analog frequency/current signal output.
Multi-step selection 0 to 15, Jog, accel/decel inhibit, first to forth accel/decel switches,
counter, PLC operation, external Base Block (NC, NO), etc.
150% of rated current for 1 minute
Digital Inputs DI1 to DI6 can be combined to offer various modes of operation,
RS-485 serial interface (MODBUS).
Set by RUN, STOP and JOG