Param
No.
EDS Values
Read/Write
Default
Value
(EDS)
Parameter
Range
Comments
22
FlowSensorHi-
LoWarningSp
Read
1
0 –
2147483647
Displays the Flow high
warning band set point in
μL
23
FlowSensorLo-
LoAlarmSp
Read
1
0 –
2147483647
Displays the Flow low
alarm band set point in μL
24
FlowSensorHi-
HiAlarmSp
Read
1
0 –
2147483647
Displays the Flow high
alarm band set point in μL
25
FlowTotaliser
Read
0
0 –
2147483647
Displays the totalised flow
value in deci-ml
26
RevolutionCount
Read
0
0 –
2147483647
Displays the revolution
count in full rotations
27
PumpSpeed
Read
100
1 - 3600
Displays the current pump
speed set point in deci rpm
28
SpeedLimit
Read
3600
1 - 3600
Displays the current speed
limit set point in deci rpm
29
GeneralAlarm
Read
0
0 – 32767
Displays a value
corresponding to pump
alarms.
30
PumpVersionMajor
Read
0
0 – 127
Pump software version
major revision number
31
PumpVersionMinor
Read
0
0 – 127
Pump software version
minor revision number
32
ASIC-VersionMajor
Read
0
0 – 127
Ethernet ASIC software
version major revision
number
33
ASIC-VersionMinor
Read
0
0 – 127
Ethernet ASIC software
version minor revision
number
34
ASIC-VersionBuild
Read
0
0 – 127
Ethernet ASIC software
build revision number
m-730sn-en-08
71
Summary of Contents for 730 S
Page 14: ...8 3 Pumphead options 730 pump range 720R 720R RX 720RE 720RE REX 14 m 730sn en 08...
Page 21: ...1 2 m 730sn en 08 21...
Page 37: ...13 7 Network topology Star network Ring network m 730sn en 08 37...
Page 119: ...23 Help 23 1 Help Select Help from the main menu to access the help screens m 730sn en 08 119...