Error code
Error condition
Suggested action
Er 3
FLASH corruption
Attempt to reset by switching power OFF/ON. Or seek
support.
Er 4
FRAM shadow error
Attempt to reset by switching power OFF/ON. Or seek
support.
Er 9
Motor stalled
Stop pump immediately. Check pumphead and tube.
Power OFF/ON may reset. Or seek support.
Er10
Tacho fault
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er14
Speed error
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er15
Over current
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er16
Over voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er17
Under voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er20
Signal out of range
Check analog control signal range. Trim signal
as required. Or seek support.
Er21
Over signal
Reduce the analog control signal.
Err50
Communication error (internal
pump communications error and
not a network error)
Attempt to reset by switching power OFF/ON.
Or seek support.
24.2
Technical support
Watson-Marlow Fluid Technology Group
Falmouth, Cornwall
TR11 4RU
UK
Contact your local Watson-Marlow representative for support.
www.wmftg.com/contact
m-730sn-en-08
121
Summary of Contents for 730 S
Page 14: ...8 3 Pumphead options 730 pump range 720R 720R RX 720RE 720RE REX 14 m 730sn en 08...
Page 21: ...1 2 m 730sn en 08 21...
Page 37: ...13 7 Network topology Star network Ring network m 730sn en 08 37...
Page 119: ...23 Help 23 1 Help Select Help from the main menu to access the help screens m 730sn en 08 119...
Page 125: ...Refitting 1 2 3 m 730sn en 08 125...