Parameter
730 default
Output 2 - status
High = CW
Output 3
Auto/man
Output 3 - status
High = auto
Output 4
General alarm
Output 4 - status
High = alarm
The pump is now ready to operate according to the defaults listed above.
Note: The display background colour changes according to running state as follows:
l
White background indicates pump stopped
l
Grey background indicates pump running
l
Red background indicates error or alarm
All operating parameters may be changed by means of key-presses (see section
).
If the Auto restart feature is enabled it may cause the pump to start as soon
as power is turned on.
Auto-restart only affects operation of manual mode, network mode and
memodose mode.
If Auto restart is enabled the "!" Symbol is shown on the screen to warn users
that the pump may operate without any manual intervention (pump resumes
with previous settings).
Do not use auto restart for more than 12 times in 24 hours. We recommend
remote control where a high number of starts is required.
If the pump is configured to network mode or analog mode it will respond to
remote commands at any time including immediately after power on. The "!"
Symbol is shown on the screen to warn users that the pump may operate
without any manual intervention (e.g. a remote setpoint could start the pump
with no key press required).
m-730sn-en-08
41
Summary of Contents for 730 S
Page 14: ...8 3 Pumphead options 730 pump range 720R 720R RX 720RE 720RE REX 14 m 730sn en 08...
Page 21: ...1 2 m 730sn en 08 21...
Page 37: ...13 7 Network topology Star network Ring network m 730sn en 08 37...
Page 119: ...23 Help 23 1 Help Select Help from the main menu to access the help screens m 730sn en 08 119...
Page 125: ...Refitting 1 2 3 m 730sn en 08 125...