11

Product use and decontamination declaration

In compliance with the UK Health & Safety at Work Act and the Control of Substances Hazardous to Health
Regulations
 you, the user are required to declare the substances which have been in contact with the product(s)
you are returning to Watson-Marlow or any of its subsidiaries or distributors. Failure to do so will cause delays in
servicing the product. Therefore, please complete this form to ensure that we have the information before receipt
of the product(s) being returned. A FURTHER COPY MUST BE ATTACHED TO THE OUTSIDE OF THE PACKAG-
ING CONTAINING THE PRODUCT(S)
You, the user, are responsible for cleaning and decontaminating the
product(s) before returning them.

Please complete a separate Decontamination Certificate for each pump returned.
RGA No: .......................

1

Company

Address

........................................

Postcode ........................................

Telephone

........................................

Fax Number ....................................

3.4 Cleaning fluid to be used if residue of chemical is found during

2 Product

servicing;

2.1 Serial Number ................................

(a)

2.2 Has the Product been used?

(b) ……………………………………………

YES

     NO

(c) ……………………………………………

(d) ……………………………………………

If yes, please complete all the following

Sections

If no, please complete Section

5 only

3 Details of substances pumped

4  I hereby confirm that the only substances(s) that the equipment
specified has pumped or come into contact with are those named, that the
information given is correct, and the carrier has been informed if the

3.1 Chemical names:

consignment is of a hazardous nature.

(a) ....................................................... 5 Signed ……………………………………………….. ...........

(b) .......................................................

Name …………………………………………………

(c) .......................................................

Position ……………………………………………….

(d) .......................................................

Date …………………………………………………..

 3.2 Precautions to be taken in
handling these substances:

(a) ........................................................

(b) .......................................................................................................

(c) ........................................................

(d) ........................................................

3.3 Action to be taken in the event of human contact:

(a) ………………………………………………………………….

(b) ………………………………………………………………….

(c) ………….………………………………………………………

(d) ………….………………………………………………………

Watson-Marlow Limited   Falmouth   Cornwall   TR11 4RU   England   Tel: 01326 370370   Fax: 01326 376009

Note: To assist us in our servicing
please describe any fault condition you
have witnessed.

Summary of Contents for 621 Trio

Page 1: ...621 Trio 621tr gb 02 pdf...

Page 2: ...ted to malicious or accidental damage or electrical surge are excluded Warranties purporting to be on behalf of Watson Marlow Limited made by any person including representatives of Watson Marlow Limi...

Page 3: ...power off and wait one minute so that the dc link capacitors can discharge Some parameter settings can start the motor automatically after a mains failure The Trio inverter is not to be used as an eme...

Page 4: ...htening torques are used Access cover retaining screws 2 5Nm Gland hole covers 1 0Nm Mains connector screws 1 0Nm Control connector PL700 0 4Nm Check the supply voltage is correct for the inverter use...

Page 5: ...link from DIN1 pin 5 and P10 pin 1 to DIN2 pin 6 and P10 pin 1 on the control cable connector see Figs 2 and 3 b Apply mains power The green and yellow LEDs will illuminate to show that power is appl...

Page 6: ...r direction 5 F current S setpoint frequency 6 Motor rpm 7 Motor voltage 8 Motor torque max Other OPm2 functions The parameter settings required can be entered using the three buttons P I and J on the...

Page 7: ...e on off switch This sets up the inverter for clockwise rotation default If counter clockwise operation is required connect a switch between control terminals 6 and 1 d Connect the OPm2 and set parame...

Page 8: ...ault Switch off power and switch on again F012 External trip PTC Check if motor is overloaded F013 Programme fault Switch off power and switch on again F018 Auto restart after fault Automatic re start...

Page 9: ...resistor hot System Parameters Note In the following parameter table l Indicates parameters that can be changed during operation Indicates that the value of this factory setting depends on the rating...

Page 10: ...power for motor kW hp P086 l Motor current limit 150 P087 Motor PTC enable 0 P088 Automatic calibration 0 1 P089 l Stator resistance W P091 l Serial link slave address 0 P092 l Serial link baud rate 6...

Page 11: ...ate for each pump returned RGA No 1 Company Address Postcode Telephone Fax Number 3 4 Cleaning fluid to be used if residue of chemical is found during 2 Product servicing 2 1 Serial Number a 2 2 Has t...

Reviews: