Watlow D4T Data Logger
•
88
•
Chapter 5 Function Reference
Output Point 7
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 7 and less than Input Point 8.
Range: -99,999.000 to 99,999.000
Input Point 8
Set the eighth lowest input value to be scaled. Input values equal to or greater than this, but
less than Input Point 9 are scaled to Output Point 8.
Range: -99,999.000 to 99,999.000
Output Point 8
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 8 and less than Input Point 9.
Range: -99,999.000 to 99,999.000
Input Point 9
Set the ninth lowest input value to be scaled. Input values equal to or greater than this, but
less than Input Point 10 are scaled to Output Point 9.
Range: -99,999.000 to 99,999.000
Output Point 9
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 9 and less than Input Point 10.
Range: -99,999.000 to 99,999.000
Input Point 10
Set the tenth lowest input value to be scaled. Input values equal to or greater than this are
scaled to Output Point 10.
Range: -99,999.000 to 99,999.000
Output Point 10
Set the value to which the input is scaled when the input is greater than or equal to Input
Point 10.
Range: -99,999.000 to 99,999.000
Offset
Set an adjustment to the final value, added after scaling.
Range: -99,999.000 to 99,999.000
Linearization Errors
When the input has an error the signals connected to the output have the same error.
Error Condition
Result
Input has an error
The output propagates the same error.