21
7.5 LED status indicator
1.
Red flashing LED:
Battery <80% charged
2. Yellow flashing LED:
Battery >80% charged
3. Green flashing LED:
Battery 100% charged
4. Green LED steady on:
Battery charging is complete, the charger switches off auto
matically
7.6 Error identification
Red or red - green flashes every 3 seconds: problem from battery
Solution: 1. There is a short circuit in the system, measure your
system. 2. The battery may be overheated. Place the battery in a
well-ventilated area.
Yellow flashes every 3 seconds: mains problem
Solution: check if the input voltage is correct. A problem could be
that the cables to the input side of the charger are too thin or too
long.
Green flashes every 3 seconds: Trouble from battery charger
Solution: The battery charger has overheated. Place the battery
charger in a well-ventilated area and make sure the fan can run
properly. The air through the heat fins of the charger must be able
to blow freely.
7.2 Charging the battery
The battery is charged to a Voltage of 56.8 V. The battery starts
charging with a constant current stated as the max charging cur-
rent on the charger. When the battery reaches its max Voltage
the charger will continue charging at constant Voltage. When
the battery is fully charged the charger turns of. NOTE: there is no
float charging stage! This is to increase the battery lifetime.
Constant current
: charging at max current as stated on the char-
ger.
Constant voltage
: charging at max Voltage as stated on the
charger.
Use information
Battery chemistry
Lithium Iron Phosphate
Input voltage
220V AC +/- 20%
Input current
≤13A
Output voltage
56.8V
Output current
35A
IP rating