background image

14

Connecting multiple batteries in parallel can be done in the 
following ways of which method 2 is preferred:

Method 1: Note different cable thiknesses have to be used due to 
the difference in current. 

IMPORTANT

: for each battery the total 

cable length of the negative side needs to be the same length as 
the positive side.

Method 2: Using a positive and a negative busbar to connect the 
batteries to makes it easier to handle the currents. IMPORTANT: 
make sure each battery has equal cable lengths between the 
busbar and hte battery for both the negative and the positive 
sides.

-

100 A

200 A

100 A

100 A

300 A to Motor

+

100 A

200 A

100 A

100 A

300 A to Motor

+

100 A

100 A

100 A

300 A to Motor

300 A to Motor

-

Increment parallel connections -->

+ Busbar

- Busbar

Summary of Contents for 48-6500

Page 1: ...Version 1 2 2 English 48 6500 48 6500 Lithium Iron Phosphate battery...

Page 2: ...2 Water World Electronics Weerdijk 14 8375 AX Oldemarkt info ww el com Telefoon 0561 451 636 www ww el com...

Page 3: ...ions carefully to maintain our high standards during installation and operation of the battery Also reading the manual will teach you how you can get the best out of your system and increase its longe...

Page 4: ...ltiple batteries in parallel 13 5 2 Installation 15 5 3 Wiring 15 5 4 Ventilation 16 5 5 Checking your system 16 5 6 Switching the battery on and off 16 5 7 Connecting the WaterWorld Battery Link 16 5...

Page 5: ...site www ww el com downloads By reading and following these instructions you will Avoid dangers to yourself and your surroundings Reduce outage times and repairs Increase the lifetime of your battery...

Page 6: ...rld drivetrain The following components are included in the product package 1x Battery Link module 1x User manual 1x RJ45 waterproof data cable 2 2 Overview and controls of WW 48 6500 1 Power Button 2...

Page 7: ...n An open terminal is NOT waterproof Expansion valve The expansion valve regulates air pressure between the inside of the battery and its outside environment The valve is waterproof as long as it is n...

Page 8: ...te LFP LiFePO4 Battery management and safety On off switch Yes Cell balancing Yes High current and short circuit protection Yes Deep discharge protection Yes cut off at 41 6 V individual cell string v...

Page 9: ...identifica tion Yes Error identification Yes Use information Ambient temperature dis charging 10 C up to 45 C Ambient temperature charging 0 C up to 45 C Ambient temperature storage 25 C up to 60 C Ty...

Page 10: ...WaterWorld electric drive systems in combination with the WaterWorld com munication gateway The maximum power output of the battery is 5120 Watt It is important to realise that when a bigger load is...

Page 11: ...ease read the following carefully Danger Risk of fatal electric shock Contact with uninsulated or damaged parts may lead to elec tric shock resulting in death or severe physical injuries Never do any...

Page 12: ...lectrical equipment Never leave tools in contact with the battery but store them away at a safe distance Always be aware of the polarity of the battery terminals Make sure you connect the battery at t...

Page 13: ...e to first discon nect the black negative terminal before disconnecting the red positive terminal Never transpose the polarities 5 1 Connecting multiple batteries in parallel Danger Never connect the...

Page 14: ...needs to be the same length as the positive side Method 2 Using a positive and a negative busbar to connect the batteries to makes it easier to handle the currents IMPORTANT make sure each battery has...

Page 15: ...ssible and are not in contact or close near any other objects that can damage the components Make sure the equivalation valve on the battery is not obstructed from functioning properly 5 3 Wiring Warn...

Page 16: ...y is turned off when the switch is level with the surface 5 7 Connecting the WaterWorld Battery Link When combining Waterworld 48 6500 batteries with a WaterWorld electric drive a system can be create...

Page 17: ...ction At low temperatures below freezing the BatteryLink protects the battery The power of the motor is reduced which gives the bat tery the chance to warm up before the maximum power can be demanded...

Page 18: ...ode The battery will go in protection mode when the battery is operating outside its specification limits There are two types of protection The first protection switches off the battery when the condi...

Page 19: ...ect polar ity Make sure the battery terminals are clean and free of corrosion The battery charger needs to be compatible with the bat tery and output 56 8 Volt 7 1 Overview of charging components The...

Page 20: ...20 AC 220V 35A to battery s Increment parallel connections Busbar Busbar AC 220V 35A to battery s Increment parallel chargers...

Page 21: ...charger Solution The battery charger has overheated Place the battery charger in a well ventilated area and make sure the fan can run properly The air through the heat fins of the charger must be able...

Page 22: ...the WaterWorld BatteryLink To read errors without a battery link the battery will have to be taken to a service station Overtemperature The battery temperature is higher than allowed according to the...

Page 23: ...s a long battery life and safe operation However there are additional actions one can take to even further extend the lifetime of your battery Since we want you to enjoy your battery for as long as po...

Page 24: ...Water World Electronics Weerdijk 14 8375 AX Oldemarkt info ww el com Telefoon 0561 451 636 www ww el com...