47
46
9. FAULTS AND ISSUES
Error codes for faults
Problems
Error codes for faults
These codes will appear on your display (see also chapter 6 under ‘Explanation of the Display
“Inspect the data in the display regarding temperature, voltage, the smooth operation of the
propeller shaft installation, and the proper connection of all wiring for the following error codes. If
the problem cannot be resolved, please contact your supplier.
Voltage too low
The controller measures a voltage lower than 46 volts (minimum startup voltage) or has a voltage
temporarily lower than this measured value.
Voltage too high
The controller measures or has measured a higher voltage than the settings allow (70 volts is the
maximum voltage).
Throttle lever
The controller detects a problem in the signal from the throttle lever, typically a poor connection in
the wiring.
Engine temp.
The temperature sensor in the engine block measures a temperature above 130°C.
Error Codes:
Code
Controller:
E00
Engine_Error_None, no error
E02
Engine_Error_Motor_Hot, Stator over-temperature (engine overheating)
E08
Engine_Error_Motor_Controller_Hot, Circuit board overheating
E11
Engine_Error_Controller_UnderVoltage, Low Voltage
E12
Engine_Error_Controller_OverVoltage, High Voltage
E18
Engine_Error_Controller_Temperature, Communication Error with temperature
IC
E30
Engine_Error_Communicaition_CAN, Motor communication error (CAN BUS)
E31
Engine_Error_Communicaition_SPI, Motor communication error (SPI BUS)
E32
Engine_Error_Communicaition_Throttle, Remote throttle control communication
error
Display:
D01
LowVoltageWarning
D02
ReducePowerWarning
Battery:
B01
Battery, Low temperature
B02
Battery, High temperature
B03
Battery, Low voltage
B04
Battery, High voltage
B05
Battery, High current
B16
Battery, Vendor specific error. This error shows an hexadedimal value starting
with 0x
Throttle:
T01
Put throttle in neutral
T02
Put secondary throttle in neutral
46