Cooling Characteristic
LINE
FUNCTION
908
Flow temp setpoint at OT 25°C
909
Flow temp setpoint at OT 35°C
The controller computes the flow temperature
required for a given composite outdoor temperature
based on the cooling characteristic. This is defined
by two reference points (flow setpoint at 25°C and
at 35°C).
Flow temp setpoint at OT 25°C
This is the cooling flow temperature required when
the composite outdoor temperature is 25°C, without
summer compensation.
Flow temp setpoint at OT 35°C
This is the cooling flow temperature required when
the composite outdoor temperature is 35°C, without
summer compensation.
25°C
35°C
909
908
Flow temp
setpoint
Composite
OT
The cooling characteristic is adjusted for a 25°C
room temperature setpoint. If the room temperature
setpoint is changed the curve will automatically
adapt.
Eco
LINE
FUNCTION
912
Cooling limit at OT
913
Lock time at end of heating