- (HU01 - 05) -
Hydraulic unit / Split DHW integrated
H
Y
D
R
A
U
L
IC U
N
IT
WG
0
5
0
-16
0
D
G
H
Y
D
R
A
U
L
IC U
N
IT
WG
0
5
0
-16
0
D
G
ELECTRICAL SPECIFICATIONS
2-22
COMFORT SERIES
Model name (Hydraulic unit)
WGYA050DG6
WGHA050DG
WGYA100DG6
WGHA100DG
Model name (Outdoor unit)
WOYA060LFCA
WOHA060LFCA
WOYA060LFCA
WOHA060LFCA
WOYA080LFCA
WOHA080LFCA
WOYA100LFTA
WOHA100LFTA
Electrical heater*
(backup-heater)
Type
Copper 9W / cm
2
Power supply
Phase
1
Frequency
Hz
50
Voltage
V
230
Current
Running current
A
26.1
Max. operating
current
(Hydraulic unit)
28.2 A + 10%
Electrical heater
(DHW heater)
Type
Copper 8.5W / cm
2
Power supply
Phase
1
Frequency
Hz
50
Voltage
V
230
Current
Running current
A
6.5
Max. operating
current
(Hydraulic unit)
7.0 A + 10%
Wiring specification*
(For back-up heater power supply)
Main fuse (circuit
breaker) current
A
32
Connection cable
mm²
6.0 x 3
Wiring specification
(For DHW heater power supply)
Main fuse (circuit
breaker) current
A
16
Connection cable
mm²
1.5 x 3
Wiring specification
(Hydraulic unit to Outdoor unit)
Connection cable
mm²
1.5 x 4
Limited wiring
length
m
Not available
*: WGY model only.