- (OU01 - 02) -
Outdoor unit / 3 phase
O
U
T
D
O
O
R U
N
IT
WO
K1
1
2
-1
6
0
L
C
T
A
O
U
T
D
O
O
R U
N
IT
WO
K1
1
2
-1
6
0
L
C
T
A
High efficiency
z
Energy efficiency is improved by the Linear Control Injection Technology and the optimization
of refrigerant cycle control. High power model realizes high performance and high efficiency by
adopting twin sensors and control technology corresponding to hot water heating.
High COP
11 kW
4.30
14 kW
4.22
16 kW
A7W35 condition
4.10
Proportion of primary energy into heating
energy of 100%
Direct electrical heating
278%
117%
109%
79%
Primary Energy Consumption*
*Electricity loss is different due to power plant. Efficiency of power plant : 36%
Oil heating
Gas condensing boiler
100%
Energy
heating
Optimization of refrigerant cycle operation
Outdoor unit
Hydraulic indoor unit
Emitter system
Refrigerant
Hot water
Temperature
sensor
Pressure sensor
Co-axial Heat Exchanger
Accurate temperature control by DC inverter
technology
V-PAM inverter
technology
Time
High
T
e
m
p
e
ra
tu
re
Constant
Wide operation range
z
Improvement operation range depending
on the optimization of refrigerant cycle
control
35°C
-25°C
0°C
Outdoor temperature
Others
z
2 stage Low noise mode*
•
Peak cut function*
•