SAFETY INSTRUCTIONS
Page 2 of 20
WARNING
!
Scalding Water Hazard. May result in serious burns.
When operating the pump, be sure to open at least one discharge valve slightly to prevent the pump from
overheating. If the pump runs for a few minutes completely closed, it may heat the water enough to scald
someone when the valve is opened. Overheating can damage the packing, seals and other pump parts. If the
apparatus builder has installed a by-pass system or other provision designed to prevent overheating, opening
a discharge valve may be unnecessary.
WARNING
!
Suction and high pressure hazard.
May cause injuries to the hands, fingers or severe cuts or abrasions to the skin.
Never insert hands or fingers into the intake or discharge openings while engine is running. Never spray high pressure water
at a person or animal.
CAUTION
Pump overheat hazard.
May cause damage to the pump.
Do not run the pump dry for any extended period of time to prevent the pump from overheating.
IMPORTANT NOTES:
1. Ambient operating temperature range: -18
_
F to 118
_
F (-28
_
C to 48
_
C)
2. Maximum sound pressure level: 94 dBa @ 1.5 meters
3. The PB18 Series Portable Pumps are designed to be carried by two or more people.