![Waterous Eclipse Installation, Operation And Maintenance Manual Download Page 81](http://html1.mh-extra.com/html/waterous/eclipse/eclipse_installation-operation-and-maintenance-manual_3642883081.webp)
81
|
90
Cleaning the Wye Strainer
1
4
2
5
3
6
Use the illustrations and instructions to clean the
wye strainer. Purge the pressure from the system
before changing the wye strainer.
• Purge all pressure before
servicing.
• Liquid ejected at high
pressure can cause
serious injury.
High Pressure
1 Open the clean-out valve and allow the system
drain.
2 Remove the clean-out valve and adapting
components.
Note:
Replace any worn or deteriorated
washers or O-rings.
3 Remove the strainer from the assembly, then
clean or replace it.
4 Install the strainer into the wye fitting.
Note:
Operating the cooler without the strainer
allows debris from the water supply to
damage the system.
5 Install the clean-out valve into the wye fitting.
6 Close the clean-out valve.
Summary of Contents for Eclipse
Page 3: ......
Page 45: ...Notes...