![Waterous Eclipse Installation, Operation And Maintenance Manual Download Page 25](http://html1.mh-extra.com/html/waterous/eclipse/eclipse_installation-operation-and-maintenance-manual_3642883025.webp)
25
|
90
Oil Cooler
Feature
Feature
Description
Description
1 Oil inlet
This is the inlet for the heated oil.
2 Oil outlet
This is the outlet for the cooled oil.
3 Mounting bracket
These are used to mount the oil cooler on the apparatus.
4 Water inlet
This is the inlet for the water that cools the oil.
5 Wye strainer clean-out valve
This allows you to quickly remove accumulated debris from the wye strainer.
6 Direction of flow indicator
This indicates the direction of water flowing through the oil cooler. Water must flow through the wye strainer before
entering the oil cooler.
7 Oil drain
These allow you to drain the oil.
8 Water outlet
This is the outlet for the water that cools the oil.
9 Water drain
This allows you to drain the water from the cooler to prevent freezing. The drain components are application-specific and
supplied by the installer.
Summary of Contents for Eclipse