Pressure Modulation Control (PMC) Assembly
Feature
Feature
Description
Description
1 Pressure sensor
This activates the pressure switch when the PMC reaches a predetermined pressure.
2 Blowdown valve
This bleeds off any remaining air in the system when it shuts down.
3 Pressure regulator
This regulates the air circuit in fixed mode and limits the system's maximum pressure in auto mode.
4 Manual adjustment screw
This calibrates the air pressure in fixed mode.
5 Mounting bracket
This is used to mount the PMC on the compressor assembly.