F-1031, Section 2112 

Page 2 of 15 

 

Safety Information

 

 

 
 

Read through the safety information and operating instructions carefully before  
using your Waterous Fire Pump.

 

 

 

!   

WARNING

 

!   

WARNING

 

Death or serious personal injury might occur if proper 
operating procedures are not followed. The pump  
operator, as well as individuals connecting supply or 
discharge hoses to the apparatus must be familiar 
with these pump operating instructions as well as 
other operating instructions and manuals for the 
apparatus, water hydraulics and component 
limitation. 

 

 

!   

WARNING

 

 

 
 
 
 
 
 
 
 
 

Pressure Hazard. May result in personal injury. 

Prior to connection or removal of hoses, caps or other 
closures with pump intake or pump discharge 
connections, relieve pressure by opening drains or 
bleeder valves. Bleeder valves should also be used 
while filling a hose connected to an intake with water. 

Scalding Water Hazard. May result in serious 
burns. 

When operating the pump, be sure to open at least 
one discharge valve slightly to prevent the pump from 
overheating. If the pump runs for a few minutes 
completely close, it may heat the water enough to 
scald someone when the valve is opened. 
Overheating can damage the packing, seals and 
other pump parts. If the apparatus builder has 
installed a bypass system or other provision designed 
to prevent overheating, opening a discharge valve 
may be unnecessary. 

Summary of Contents for CR Series

Page 1: ...or in Relay 8 Pumping from Draft 9 Fire Hose Testing 10 Lubrication CR Models 11 CRU 1 CRU 2 Models 12 14 Mechanical Seal 15 Overheat Protection Manager 15 Read through the installation instructions...

Page 2: ...personal injury Prior to connection or removal of hoses caps or other closures with pump intake or pump discharge connections relieve pressure by opening drains or bleeder valves Bleeder valves shoul...

Page 3: ...f a fire pump on a fire department apparatus is used for service testing of fire hoses the procedures in NFPA 1962 MUST be followed including the use of a fire department gate valve with a inch 6 mm h...

Page 4: ...ess steel shaft bronze wear rings mechanical seal and related parts The impeller is mechanically and hydraulically balanced and the impeller shaft is supported by ball bearings Mechanical Seals Mechan...

Page 5: ...F 1031 Section 2112 Page 5 of 15 Available Models Model CR Direct Drive Model CRU 1 Direct Drive Model CRQA Model CRUQC 2 Model CRQB Model CRQC IL3838 IL1806...

Page 6: ...6 of 15 Available Models con t Model CRUQC 2 with Bell Housing Adapter Model CRUC21 2 Model Rear Facing CRUC21 2 Pump mounted on front input shaft side of transmission Pump mounted on rear output sha...

Page 7: ...es of impurities 3 If pump is kept full of water when not in use make sure water is clean and non corrosive Make sure the pump is completely full or completely drained never partially full NOTICE WARN...

Page 8: ...operly with higher in take pressure but will accelerate mechanical seal wear 1 Engage pump drive 2 Open intake hydrant and other valves as necessary to allow water to enter the pump NOTE Bleeder valve...

Page 9: ...Make sure no part of hose is higher than pump inlet Air pockets in intake hose may cause loss of prime or erratic pump action and may reduce pump capacity c Make sure all intake connections are tight...

Page 10: ...ire hoses the procedures in NFPA 1962 MUST be followed including the use of a fire department gate valve with a inch 6 mm hole drilled through the gate installed between the fire apparatus discharge o...

Page 11: ...isted vary based on ratio and or mounting orientation 5 Be sure to clean the drain plug and breather 6 Synthetic oil substitutes are acceptable NOTICE Fluid temperature hazard May cause premature seal...

Page 12: ...emperature Over 90 F SAE 20 Oil 300 SSU 100 F with service classification SA SB SC should be used Model CRQA For Ambient Temperature Over 90 F SAE 20 Oil 300 SSU 100 F with service classification SA S...

Page 13: ...service classification SA SB SC should be used Model CRU 1 Direct Drive For Ambient Temperature Over 90 F SAE 20 Oil 300 SSU 100 F with service classification SA SB or SC should be used Model CRUQB 1...

Page 14: ...100 F with service classification SA SB or SC should be used Model CRUQC 2 with Bell Housing Adapter Model CRUC21 2 For Ambient Temperature Over 90 F SAE 20 Oil 300 SSU 100 F with service classificat...

Page 15: ...seal If the mechanical seal leaks replace the entire seal The same drain weep hole is used to vent the mechani cal seal on the pump shaft and the oil seal for the bearing housing Inspect for water me...

Reviews: