F-1031, Section 2112
Page 11 of 15
Lubrication
1. Check the lubrication level once a month and change
after every 100 hours of operation or at least every
spring and fall. Under severe conditions where pump
has been used continuously at high output, change
more frequently.
2. Always fill to the bottom of the plug hole labeled
“Oil
Level”. Do not Overfill.
NOTICE
If fluid level is low, locate the source of the leak
and repair. If the fluid level is high, loosen the drain
3. Note that the breather may be removed and the hole
used as the lubricant fill.
4. Capacities shown are approximate, quantities listed
vary based on ratio and/or mounting orientation.
5. Be sure to clean the drain plug and breather.
6. Synthetic oil substitutes are acceptable.
NOTICE
Fluid temperature hazard.
May cause premature seal wear and d
o
amage.
o
plug until the fluid drops to the proper level. If
excessive water drains out, change the fluid
and determine the source of the water
leakage and repair.
Fluid temperature should not exceed 250 F (121
C)
Model CRU-2 Direct Drive
For Ambient Temperature Over 90
F:
SAE 20 Oil 300 SSU @ 100
F with
service classification SA, SB, SC should
be used.
Fluid temperature hazard.
May cause premature seal wear and damage.
Fluid temperature should not exceed 250
F
(121
C) for an extended period of time in order to
prevent seal wear and damage.
Lubricant
Capacity
ATF
1.50 Quarts
1.42 Liters