55
|
90
Safety Introduction Product Overview
5. Connect the cable to the control box. Refer
to:
"Connecting M12 Cables to the Control Box" on page 52
Important:
Installing the foam manifold at more than a ± 15° tilt may
cause inaccurate readings
.
Top
Figure 46
Installing the Supply Hose
The supply hose routes the concentrate from the supply tank to pump. Refer to
the
"Overview Diagram—Typical" on page 20
for the instructions in this
section. The supply hose is required to meet the following specifications:
• Minimum 3/4 inch inside diameter for AQUIS 1.5 and 3.0
• Minimum 1 inch inside diameter for AQUIS 6.0
• Minimum 23 inHg (0.78 bar) of vacuum
• Maximum 50 psi (3.45 bar) of pressure
• Reinforced clear wall as required by NFPA
1.
Route and connect the supply hose from the supply tank shutoff valve to
the foam pump intake.
Note:
Make sure that you plumb the wye fitting with strainer in-line with
the supply hose.
2.
Use cable ties to secure the hoses and wye fitting to the apparatus.
Note:
Do not pinch or kink the hose.
Note:
Do not secure the hose to hot or moving parts.
Note:
An optional hose kit is available, contact your Waterous for more
information.
Installing the Injector Hose
The injector hose routes the concentrate from the foam pump to the injector.
Refer to the
"Overview Diagram—Typical" on page 20
for the instructions
in this section. The hose is required to meet the following specifications:
• Minimum 3/8 inch inside diameter—AQUIS 1.5 and AQUIS 3.0
• Minimum 1/2 inch inside diameter—AQUIS 6.0
• Minimum 450 psi (31 bar) of pressure
1. Connect one end of the hose to the output on the foam pump.
2. Connect the other end of the hose to the concentrate injector check valve.
3. Use cable ties to secure the hoses to the apparatus.
Note:
Do not pinch or kink the hose.
Note:
Do not secure the hose to hot or moving parts.
Note:
An optional hose kit is available, contact your Waterous for more
information.
Connecting the Bypass Hose
Refer to
"Overview Diagram—Typical" on page 20
for the instructions in
this section. The hose is required to meet the following specifications:
• Minimum 3/8 inch inside diameter.
• Long enough to reach a container outside the apparatus and can be
coiled when not in use.
1. Connect the hose to the bypass port on the inject/bypass valve.
2. Secure the bypass hose until it is used.
Note:
Do not pinch or kink the hose.
Note:
Do not secure the hose to hot or moving parts.
Note:
Coil when not in use.
Fittings
Fittings connect the hoses to the various components in the system. The
fittings are required to meet the following specifications:
•
Compliment the appropriate hose specification
•
Compatible with the foam concentrate
•