background image

Assembly and Operating Instructions Sand Filter System without Pre-filter

3

KURZANLEITUNG / QUICK START GUIDE / NOTICE SOMMAIRE / GUIDA RAPIDA    

 

BEKNOPTE HANDLEIDING / KORTFATTAD BRUKSANVISNING /  

STRUČNÁ PŘÍRUČKAG / STRUČNÝ NÁVOD / KRATKA NAVODILAG / GYORS ÚTMUTATÓ    

ÎNDRUMĂTOR PE SCURT

Steigrohr

Filterstern

2

3

1

4

1

2

3

4

5

7

6

8

D

  Steigrohr einsetzen (2 unterschiedliche Versionen)

UK

 

 

Insert riser pipe (2 different versions)

F

  Remplacer le tube montant (2 versions différentes)

I

  Inserire il tubo montante (2 versioni diverse)

NL

  

Stijgbuis toepassen (2 verschillende versies)

S

  

Sätt i stigröret (2 olika utföranden)

CZ

  

Nasazení stoupací trubky (2 různé verze)

SK

  

Nasadiť stúpaciu rúru (2 rôzne verzie)

SI

  

Vstavite dvižno cev (2 različni različici)

HU

  

A felszállócső behelyezése (2 különböző változat)

RO

  

Introducerea ţevii ascendente (2 versiuni diferite)

D

  Ventil aufsetzen

UK

  Valve installation

F

  Mise en place de la vanne à 6 voies

I

  Applicare la valvola

NL

  Ventiel plaatsen

S

  Sätt på ventilen

CZ

  Nasaďte ventil

SK

  Nasaďte ventil

SI

  Namestitev ventila

HU

  A szelep felhelyezése

RO

  Amplasare supapă

D

  Filtermaterial einfüllen

UK

  Filling the filter material in

F

  Remplissage de la matière filtrante

I

  Caricare il materiale filtrante

NL

  Filtermateriaal bijvullen

S

  Häll i filtermediet

CZ

  Naplňte filtrační materiál

SK

  Naplňte filtračný materiál

SI

  Polnjenje s filtrirnim materialom

HU

  A szűrőanyag betöltése

RO

  Umplere cu material de filtrare

D

  Montage & Anschluss der Pumpe

UK

  Assembly and connection of the pump

F

  Montage et raccordement de la pompe

I

  Montaggio e collegamento della pompa

NL

  Montage & aansluiting van de pomp

S

  Montering och tillkopplingen av pumpen

CZ

  Namontujte a připojte čerpadlo

SK

  Montáž & Pripojenie čerpadla

SI

  Montaža in priklop črpalke

HU

  A szivattyú szerelése és csatlakoztatása

RO

  Montarea şi racordarea pompei

Summary of Contents for SF 122

Page 1: ...rating Instructions Sand filter system English Illustrations are exemplary Sand filter system SF 122 124 Sand filter system small without pre filter Please read this manual carefully and keep it for f...

Page 2: ...en CZ Smontujte filtra n syst m SK Namontujte filtra n zariadenie SI Monta a filtrirne naprave HU A sz r berendez s sszeszerel se RO Montarea instala iei de filtrare D Filteranlage muss unterhalb des...

Page 3: ...n F Mise en place de la vanne 6 voies I Applicare la valvola NL Ventiel plaatsen S S tt p ventilen CZ Nasa te ventil SK Nasa te ventil SI Namestitev ventila HU A szelep felhelyez se RO Amplasare supap...

Page 4: ...ad waterman pool com SK Podrobn n vod vo va om jazyku n jdete na internete na str nke http download waterman pool com SI Celotna navodila v Va em jeziku najdete na spletni strani http download waterma...

Page 5: ...N FECHADO NCHIS Z RT ZAPRTO RECIRCULATE RECIRCULATION RECIRCULACION RICIRCOLO ZIRKULIEREN RECIRCULACAO RECIRCULARE KERINGTET S OBTOK WASTE VIDANGE VACIADO SCARICO ENTLEEREN ESVAZIAMENTO GOLIRE R T S I...

Page 6: ...Small 4 2 2260101 Filter tank 250mm grey X 2 2260106 Filter tank 250mm grey X 2 2260105 Filter tank 300mm blue X 2 2260150 Filter tank 330mm grey 3 590000014 Drain valve 27mm round hole X X X 4 226011...

Page 7: ...stem FH 4m tank 330mm Art no 45116000 Sand filter system SF 124 Art no 502010480 Sand filter system SF 124 Konifera Art no 502010490 Sand filter system SF 124 OBI Art no 502010497 X X X X X Alternativ...

Page 8: ...thout Pre filter 8 English COMPONENTS OF THE FILTER SYSTEM 1 Pump 2 Filter tank 3 Drain valve 4 Filter pallet 5 Multiway valve 6 Connecting hose pump valve 1 2 3 5 6 4 OR Riser pipe model 2 Each deliv...

Page 9: ...e 6 way valve only when the pump is switched off Filter systems with non self priming pump must be installed below the water level TABLE OF CONTENTS 1 Filter system Description 1 1 Description of 6 wa...

Page 10: ...1 FILTER Filtration operating state In this position the swimming pool water is pumped through the filter tank and quartz sand and then back to the pool The dirt is filtered out via the quartz sand 1...

Page 11: ...e swimming pool water by means of a special quartz sand for swimming pools 0 4 0 8 mm or other filter medium e g filter glass or filter balls This is done at a pressure of 0 4 0 8 bar When the pressur...

Page 12: ...doing so please mount a rubber seal each from the inside and from the outside and then fix the drain valve with the lock nut from the outside Step 3 Instructions for model with riser pipe 1 At first...

Page 13: ...r operation Step 8 Carefully fill the correct amount of quartz sand see table in from the top into the filter tank and ensure that the riser pipe remains in the correct central position About two thir...

Page 14: ...e rubber hose fitting only included with 2260140 and 2260148 pump into the connecting hose and insert in on the upper pump connection as far as possible Then fix it firmly with a hose clip Step 13 Fas...

Page 15: ...mer the water automatically runs into the pump If necessary we recommend the installation of a gate valve in addition It can be used to interrupt the water flow of the filter system 2 3 2 SYSTEM WITH...

Page 16: ...on swimming pool size water volume bather load weather and the used chemicals Example It is recommended to recirculate the pool volume 1 to 1 5 times in 24 hours If a pool volume of 10 m is circulate...

Page 17: ...dual dirt after backwashing into the sewer system instead of the swimming pool To do this set the 6 way valve to RINSE Switch the filter system on for a maximum of 30 seconds then reset the 6 way valv...

Page 18: ...from the filter tank and store the entire filter system in a frost protected area e g in the basement Do not push or transport the filled tank otherwise there is a risk of breakage 6 TROUBLESHOOTING...

Page 19: ...BETWEEN PUMP HOUSING AND MOTOR 1 During commissioning it is possible that water escapes in drops at intervals of approx 2 minutes After a few hours of operation when the seal has run in the dripping s...

Page 20: ...es not start Incorrect voltage Compare pump voltage with mains voltage Foreign particles in the pump Clean pump Thermal protection relay has responded Reset thermal circuit breaker and determine cause...

Page 21: ...s where modifications are made to the delivered goods parts are replaced or consumables are used for these products that do not meet the original specifications Customer claims for damages e g for non...

Page 22: ...ought from company at Postcode Town the product model with article number I want to submit the following complaint Please include a precise description Place Date Signature Required information docume...

Page 23: ...you attach a proof of purchase to your claim A proof of purchase like a sales receipt is a mandatory prerequisite for all warranty claims Without proof of purchase it is unfortunately not possible for...

Page 24: ...DO NOT RETURN TO THE STORE Questions Problems Missing parts Please contact our customer hotline if you need any help Waterman Customer Service Bahnhofstr 68 73240 Wendlingen Germany Tel 49 0 7024 404...

Reviews: