10.
Connect power to
WL2FLT
Water Treatment System.
Compressor Test
11.
Red Heater & Compressor to be in the on position
I=ON
. Always ensure tanks are
full of water
before turning on the heater or the overload (high limit) will open
and require manual reset. If the wire condenser at back of the unit is warm, the
refrigeration system is working.
I=ON
12.
Once the
WL2FLT Water Treatment System
reaches its target temperature, the compressor will
shut off. Draw a glass of cold water and verify it is has chilled to proper temperature <46F.
Heater Test
13.
Always ensure tanks are full of water before turning on the Heater or the Overload (High Limit)
will open and require manual reset. It will take the heater approximately 10 minutes to heat the
water from ambient 24°C (75°F) to the factory set point of 87°C (187°F). Dispense a cup of hot
water to ensure the temperature/odor/taste is acceptable.
WARNING!
HOT WATER CAN BURN OR SCALD.
The
WL2FLT Water Treatment System
produces Hot Water up to 87°C (187°F).
Water above 52°C (125°F) can cause severe burns or