WL2FLT
Manual Page 5
–
Revision 10-26-2021
WARNING!
DO NOT OPERATE IF DAMAGED.
Unplug and isolate water supply if abnormal
conditions exist. Contact Waterlogic or authorized dealer for repair, service, and installation to
avoid hazards.
WARNING!
HOT WATER. Unit produces Hot Water in excess of 80
o
C (175
o
F).
Water above 52
o
C
(125
o
F) can cause severe burns or scalding. Keep unauthorized people and children away from the
unit to avoid accidental dispensing of hot water.
WARNING!
CONNECT TO POTABLE WATER SUPPLY.
This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system.
WARNING!
TIP HAZARD.
Dispenser could tip or fall causing serious injury. Always install unit on a
firm, flat, and level surface and secure unit to cabinet, wall, or floor if needed. Never place heavy
items on top of unit and never climb, stand, or hang on unit or storage cabinet to prevent injury
and damage.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED.
Transport unit empty and always use
material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be
completely drained
before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Always sanitize before use to
eliminate any potential microbiological contaminates.
CAUTION!
INDOOR USE ONLY.
Intended for Household Use.
Never expose to direct sunlight,
heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F). Install indoors
and keep unit away from excessive humidity. Never expose to freezing temperatures. Ensure
there is adequate clearance around the unit to allow refrigeration system condenser to dissipate
heat. Warmer environments require more clearance around the unit. Minimum clearance around
all surfaces of the machine is 2-inches. Installs where the ambient temperature exceeds 27°C
(80°F), require a minimum of 4-inches clearance for proper heat dissipation and efficient
operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 40 psi to 60 psi. Be
aware of any potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold
water supply only.
Feed water over 37°C (100°F) can damage the treatment components. Water
block devices and external leak detectors are strongly recommended. Locate the unit as close to
the water supply and the electrical connections as possible. Locate the unit as close to the water
supply and the electrical connections as possible. Immediately isolate or close water supply valve
and contact service representative if leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.