infiniti
Operating, Installation, and Service Manual Page 11 - Revision: 9-15-2016
PROGRAMMING INSTRUCTIONS
CHANGING ENERGY SAVER MODE TO NON ENERGY SAVING MODE
Infiniti UV
Water Treatment System
comes programmed to Energy Saver Mode. To turn off the
Energy Saving Mode, move the Jumper on CH6 from Pins 1-2 to Pins 2-3
Infiniti UV
is programmed in Energy Saving Mode
from the factory
Jumper Pin Position – Pin 1 and 2
Turn off Energy Saving Mode
Jump Pin Position – Pin 2 and 3
Display PCB – P/N EN-0033-L00-00
Pin Numbers
1
2
3
Jumper Pin Part
Number EN-6082
WLCP PN 20-
1005
1
2 3
2