background image

 

Waterlogic 

77 McCullough Drive – Suite 9 

New Castle, DE  19720 

(888) 826-6597 

Tech Portal Website:  www.techportal.waterlogic.com

 

infiniti

  

OPERATING, INSTALLATION, AND SERVICE MANUAL 

 

 
  

 

Summary of Contents for infiniti

Page 1: ...Waterlogic 77 McCullough Drive Suite 9 New Castle DE 19720 888 826 6597 Tech Portal Website www techportal waterlogic com infiniti OPERATING INSTALLATION AND SERVICE MANUAL...

Page 2: ...niti Water Treatment System provides exceptional quality and great tasting water with every use TABLE OF CONTENTS Features and Benefits 3 Certifications 4 Introduction and Safety Alert Symbols 5 Safet...

Page 3: ...the growth of microorganisms providing additional surface protection Leak Detection infiniti Water Treatment Systems are supplied with a Sensor in the Leak Tray that halts water supply to prevent ove...

Page 4: ...Systems This System has been tested and certified in accordance with NSF ANSI 61 Certified Drinking Water System Components NSF ANSI 372 Drinking Water System Components for low Lead Content and CSA...

Page 5: ...l Products manufactured and marketed by Waterlogic and its affiliates are protected by patents issued or pending in the United States and other countries Waterlogic reserves the right to change the sp...

Page 6: ...his system to be used for water only and is not intended for use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system The s...

Page 7: ...105 C Recommended Service Pressure 40 60 psi 275 414 kPa Use Pressure Regulator Maximum Service Pressure 100 psi 689 kPa Use Pressure Regulator Rated Service Flow 0 5 gallons per minute 1 89 Lpm Envi...

Page 8: ...Water Press and Release the Hot Water Selection Button followed by pressing and holding the Dispense Button WARNING Unit produces Hot Water up to 188 F 87 C Water above 125 F 52 C can cause severe bu...

Page 9: ...in than out There is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamber as it is heated Water in the vent chamber is suctioned back through the o...

Page 10: ...g Installation and Service Manual Page 10 Revision 9 15 2016 Waterlogic infiniti Water Treatment System WATER FLOW DIAGRAM Water In Solenoid Valve Water Out Faucet Condenser Compressor Filter Dryer Co...

Page 11: ...stem comes programmed to Energy Saver Mode To turn off the Energy Saving Mode move the Jumper on CH6 from Pins 1 2 to Pins 2 3 Infiniti UV is programmed in Energy Saving Mode from the factory Jumper P...

Page 12: ...iti Water Treatment System and check exterior for damage Flush Filters CAUTION FILTER FLUSH REQUIRED infiniti Water Treatment Systems are not supplied with filters Filters should be configured to opti...

Page 13: ...ly and remove the water supply pipe 6 Isolate the power to the water cooler 7 Bypass the internal twist filters to avoid mixing sanitizing solution with the active carbon This is done by disconnecting...

Page 14: ...water is clear WARNING HOT CIRCUIT IS NOT SANITIZED Water in the hot circuit is not sanitary until the temperature exceeds 171oF 77 C for at least 5 minutes Heater Test 17 Always ensure tanks are full...

Page 15: ...Treatment System produces Hot Water up to 188 F Water above 125 can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid injury Disable Cold and Ho...

Page 16: ...Compressor Power Switch is turned off the heater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to scaldin...

Page 17: ...ad bracket to access rear of filter heads 5 Disconnect tank line feed lines from hot and cold inlet solenoids at rear of filter head fittings 6 Catch hot hot water should have cooled down after dispen...

Page 18: ...s and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer e...

Page 19: ...ater is obtained Once a continuous flow is obtained release the main dispensing button Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Heater Power Switch must be in the...

Page 20: ...tat adjustment screw under the decal at the rear of the unit Remove the red portion of the Cold Tank Temperature label to access the adjustment screw The factory set point is 41 F and is indicated by...

Page 21: ...om Waterlogic Dealer See Parts Layout Drawing and Parts List for additional repair parts Hot Tank Service Hot Tanks with controls must be replaced at least every 3 5 years depending on usage Descaling...

Page 22: ...STAINLESS STEEL TANK DESCALING The hot tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe...

Page 23: ...ustomer s satisfaction WARNING HOT WATER The infiniti Water Treatment System produces Hot Water up to 188 F Water above 125 can cause severe burns or scalding Hot water should be dispensed carefully i...

Page 24: ...hrough the condenser coils on the rear of the unit you will see the hot tank located on the right hand side 5 From the front of the Water Treatment System reach up behind the hot tank and take hold of...

Page 25: ...by depressing the top flap of the Protective Metal Box so it snaps back into its original position on the hot tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compresso...

Page 26: ...infiniti Operating Installation and Service Manual Page 26 Revision 9 15 2016 Waterlogic infiniti PARTS DRAWING AND PARTS LIST Wetted Parts...

Page 27: ...ounter Top Only ST 8153 Side Panel Charcoal Tower Only 2 PU 4028 A Bulkhead Union x John Guest P N PI1208S 2 1 PU 4066 A Stem Elbow Connector Acetyl John Guest PN PI220808S Counter Top Only 3 EN 0033...

Page 28: ...l Silver Tower Only 11 PL 1159 Bottom Front Panel Charcoal Tower Only 12 PL 1011 Faucet Counter Top Only 12 1 PL 1013 Faucet Nipple Blue with Screen 12 2 CT 2007 Natural Faucet O Ring Silicon White 12...

Page 29: ...Only PL 1208 CN Rubber O Ring for ST 8138 Filter Bracket Tower Only 17 CO 9001 A Compressor R134a 1 8HP 110V 60Hz 18 PL 1251 CN Unit Rubber Feet Counter Top Only ST 8167 CN Unit Rubber Feet Tower Only...

Page 30: ...e Harness with Leak Detection Counter Top Only EL 0089 L00 00 Main Wire Harness with Leak Detection Tower Only 20 PL 0107 L00 CS Top Cover Charcoal 20 1 ST 0080 L00 00 High Voltage Metal Cover ETL Cer...

Page 31: ...ded Nut Counter Top Only 25 2 CT 2001 B UV Lamp Silicon Fixing Rubber Counter Top Only 25 3 CT 2062 CN Quartz Sleeve 100mm Counter Top Only 25 4 CT 2006 Black O Ring for Quartz Sleeve Counter Top Only...

Page 32: ...ly 32 CO 9031 Wire Condenser Counter Top Only CO 9027 Wire Condenser Tower Only 33 PU 4014 A LPDE Blue Tube 8mm 5 16 John Guest PN PE 0806 100M B 34 PU 4007 A Reducing Elbow 5 16 to elbow Connector Jo...

Page 33: ...on and Service Manual Page 33 Revision 9 15 2016 infiniti ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technician...

Page 34: ...Alarm Dispense buttons all flash at same time Possible Reason Solution Water exiting drip tray due to being full Empty Drip Tray and dry out inside of unit Leak in infiniti Water Treatment System Wat...

Page 35: ...un out of cold water Cold tank capacity is 4 liters for Tower and 2 liters for Counter Top Wait for cold tank to chill water to temperature prior to dispensing more cold water A greater capacity of Wa...

Page 36: ...it The infiniti Water Treatment System does NOT have Extra Hot capability and the maximum hot temperature is 189 F It typically takes 10 minutes for the 500W to heat the 1 6 Liter of room temperature...

Page 37: ...onfirm proper connections to the heating elements Hot tank life is 3 5 years depending on usage Typically dealers swap out the hot tank at site take back to the shop to repair Heating Coil not Working...

Page 38: ...hrough the condenser coils on the rear of the unit you will see the hot tank located on the right hand side 5 From the front of the Water Treatment System reach up behind the hot tank and take hold of...

Page 39: ...by depressing the top flap of the Protective Metal Box so it snaps back into its original position on the hot tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compresso...

Page 40: ...Chill 4 Compressor is Not Running Red Heater and Power Switch won t light and the Red LED on the Front won t light Possible Reason Solution Circuit Breaker Check the Circuit Breaker Fuse is Blown Repl...

Page 41: ...operly connect Bad Front PCB Replace Front PCB P N EN 0033 L00 00 Defective Red Heater and Power Switch Replace Red Heater and Power Switch Compressor Runs But Does Not Chill Possible Reason Solution...

Page 42: ...osition Turn Red Heater and Power Switch on I ON Compressor Starting Circuit Turn Red Heater and Power Switch off O OFF Remove the compressor cap on side of the compressor Disconnect the black and red...

Page 43: ...the Vent Hole 5 Hot Water coming out of Faucet Vent Hole 6 Restricted Flow of Hot Water 7 Hot Water Drip out of Faucet 8 No cold water available 9 Water does not dispense from unit 10 Cold Water dispe...

Page 44: ...ose or bad connection on the Front Dispensing PCB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB have been ruled out then it is...

Page 45: ...to correct faucet attachments Connect tubing to outlets as needed Hot Water Coming out of Faucet Vent Hole Possible Reason Solution Improper tubing attachment from the tank to faucet or vice versa Ve...

Page 46: ...video on the Partner Area of the Waterlogic com website for more information Tubing is creased or has a kink in it Inspect and replace tubing as necessary Faucet nipple screen mesh has obstruction s...

Page 47: ...the top to the faucet The hot tank outlet tube has a restrictor in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the tank...

Page 48: ...much water coming out of cold solenoid Replace solenoid as necessary No Cold Water Available Possible Reason Solution Closed Water Supply Valve Open the Water Supply Valve Cold Water Solenoid Valve ma...

Page 49: ...Tip the unit slightly to drain dry bottom tray completely Hot and Cold Solenoid connections into the Display PCB are loose Turn power off unplug the unit and visually inspect solenoid connections into...

Page 50: ...sealing of component Pre determine whether water being dispensed is hot cold Isolate the water supply push the DISPENSE button to release the line pressure and remove the coil affixed to the solenoid...

Page 51: ...released to the faucet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On th...

Page 52: ...TAINLESS STEEL TANK DESCALING The hot tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe m...

Page 53: ...customer s satisfaction WARNING HOT WATER The infiniti Water Treatment System produces Hot Water up to 188 F Water above 125 can cause severe burns or scalding Hot water should be dispensed carefully...

Page 54: ...tation to Waterlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporti...