11. Troubleshooting
11.1 Troubleshooting guide
Problem
Cause
Solution
Water is not dispensing.
The water supply is turned off.
The water supply pipe is kinked /
trapped. The is now power to the
machine.
Turn the water supply on. Inspect
the water supply pipe. Inspect the
mains power supply.
Water is dispensing
slowly.
The water filter is blocked
The mains water pressure is too
low.
Replace the water filter, call a
technician.
The required tempera-
ture is not reached.
Recommended usage of 16 l/h
has been exceeded. The com-
pressor is faulty.
Reduce usage.
Call service technician.
Water Leak.
The filter is not fitted correctly.
There is a leak in the system.
Check the water filter.
Turn OFF the water supply and
call technician.
The Sparkling water dis-
pense is not sparkling.
CO
2
Bottle is empty.
Replace CO
2
Bottle.
The sparkling water
button gives gas only
(no water).
The pump is not functioning
Turn off mains power, wait for
30 seconds. Turn on power, if fault
still exists call the technician.
Sparkling water dispen-
se is intermittent.
CO
2
pressure is too high.
Reduce pressure at the bottle
pressure regulator.
Sparkling water is not
sparkling enough.
CO
2
pressure to low, or bottle is
nearly empty.
Turn up the pressure at the Bottle
regulator or replace bottle.
A1 = filter end
A4 = time out cooling unit (overheating)
B1 = filter blocked
B2 = time out pomp (overheating)
generally: switch out to reset the machine