background image

7. Intended Use

 

7.1 Conditions

 

 

•     The machine is designed only for the 

dispen- se of filtered water and cooled 
filtered Water with CO

2

.

 

•     The typical usage is for the customer, guest

 

and employees.

 

•     The installation and hygiene cleaning using 

the Sanitab or Anolyte must be carried out by 
a trained technician.

 

•     The equipment is intended for use with 

a mains drinking water supply.

 

•     Local legal requirements are to be adhered 

to when installing and changing CO

bottles.

 

•     The machine must be installed on a sturdy

 

surface, free of vibration, must be dry and in- 
doors at room temperature. Do not operate in 
a cold environment, or where environmental 
conditions can be extreme. The equipment 
must be attached to a clean power supply

 

free of voltage spikes.

 

•     Maximum dispense based on 10 °C  tem- 

perature differential between water supply 
and dispense to ensure drink temperature

 

remains suitable is 16 L/Hr. Maximum volume 
in one dispense is 1 L with a 3 minute recov- 
ery period or approx. 260 ml maximum per 
minute.

 

•        Any  damage  relating  to  vandalism, 

improper  use,  or  servicing  by  an  untrained 
person will not be covered by warranty.

 

•     A spare part warranty of 24 months is inclu- 

ded. Some parts may naturally wear during 
this and are not covered, such as seals and 
lights. Items that fail due to misuse, poor wa- 
ter quality or lack of cleaning are not covered 
such as pumps and valves. The warranty 
covers manufacturing defects only.

 

•     A water filter, such as the Brita C1000AC, 

is absolutely necessary to ensure correct 
operation. The filter must be replaced at its 
rated capacity.

 

•     Regular maintenance, such as replacement

 

of seals in use of CO

2

- systems and visual in- 

spections should be carried out no later than 
six months. The cleaning of the cooling and 
the sanitation with Anolyte or sanitab and 
replacement of the aerator should also take 
place during these every 6 months.

 

•     Hygiene regulations must be observed 

whilst carrying out all cleaning and 
maintenance work.

 

Attention:

 

Please change the O3 Generator and the adapt- 
ers (A00A00A000000109) 
every 2 years.

 

 

Text content is subject to copyright.

 

 

7.2 Operational basis

 

To ensure quality of the equipment the manual 
and checklist must be complied to. Maintenance, 
care and cleaning is essential for quality ad- 
vantages: Better Hygiene and maintenance will 
make a more reliable and a fresher tasting drink, 
and will increase the life of the equipment.

 

 

7.3 Advantages of the IQ3

 

Economical because: 

No stock requirements 

as with Bottled water so no upfront funding

 

and additional storage space is not needed, no 
transportation required. The IQ3 will never run 
out of water - iQ3 will dispense 24 hours a day,

 

365 days per year!

 

 

Ecological: 

Your water is supplied fresh, without 

fuel consumption, directly to your premises, with 
no trucks, no traffic jams, no return transport of 
empty bottles, no cleaning of empties (with 
water!), no detergent. In comparison, when using 
the

 

IQ3 there is less than one tenth CO

emissions 

associated with using a bottled water cooler. 
The output is as desired: cup, glass or carafe. 
Your drink dispenses as long as you press the 
selection button.

 

 
 
 
 
 
 

 

21

 

Summary of Contents for escowa Purus iQ3

Page 1: ...Purus iQ3 Service Manual For the Installation Programming Cleaning and Maintenance...

Page 2: ...enance It is a part of the equipment and must always be available close by the machine and always be available up to the disposal of the equipment If you should loss or damage the manual you must requ...

Page 3: ...dge 17 5 1 1 Sanitation with the Service Cartridge 17 5 2 Sanitation 18 5 2 1 Sanitation with iQ sani clean SHOT using Anolyte 18 5 3 Disinfection of Dispense area 19 5 4 Ozone Generator Active Sanita...

Page 4: ...Service Record Service Equipment IQ3 Nr Water Filter Inst Date Technician Date Counter Work Carried Out Technician 4...

Page 5: ...1 Machine Construction Overview 1 1 Dismantling 3 1 1 Display and Buttons 2 Aerator with filter 2 3 Drip tray with capacity of 1 5 L 1 Chilled Still Water Sparkling Water Ambient Water Keypad Lock 3 5...

Page 6: ...1 Machine Construction Overview 1 2 Inside front cover 1 2 1 4 2 3 1 Connection for external 4 3 CO2 bottle 2 Aerator change every 12 months 3 BRITA filter 4 Disposable CO2 bottle optional 6...

Page 7: ...View from rear 1 5 4 2 3 7 6 3 1 2 1 External CO2 connection 5 4 2 Mains water inlet 3 Power supply connection 4 Programming button 5 Programming card slot 6 Machine identification plate 7 Evaporator...

Page 8: ...1 Machine construction overview 1 4 removal of covers 1 1 2 1 Undo top cover screws 2 Remove top cover first 3 Remove side covers 3 3 3 8...

Page 9: ...nal View 1 3 2 4 1 2 Left Side view 5 4 7 6 5 6 8 Right Side view 1 High pressure pump 2 Compressor Time out 4 h 3 Carbonator 4 PCB Cover 5 Ozone Generator 8 6 High pressure pump 7 Cooling fan 8 Inlet...

Page 10: ...chine construction overview 1 6 view from top 1 Thermostat 2 Relief valve 7 5 bar 3 Level probes 4 Outlet valves 3 2 1 4 5 CO2 water 6 Chilled Still water 5 7 Ambient still water 6 8 Ozone injector 7...

Page 11: ...allation setup and repair of the equip ment must only be carried out by a trained engineer The manufacturer is not responsible for damage to the equipment caused by Neglect to follow the guidelines in...

Page 12: ...1 2005 A2 2007 Safety of the electrical household appliances and similar devices 2 4 Hazard Risk Please take into account local legal requirements with regards to installation and use of CO2 com press...

Page 13: ...on 2 Chilled filtered water Selection 3 Chilled carbonated filtered water The temperature and the amount of carbonation of the water can be adjusted 3 3 Cleaning and Maintenance Before carrying out an...

Page 14: ...following page 3 1 2 4 1 Connect the mains water supply to the iQ3 Do not turn 5 the water supply on Do not attach the mains cable 2 Remove the drip tray 3 Remove the front cover 4 Installation posit...

Page 15: ...the bottle in the bracket at the front of the equipment Cut the hose to the required length and connect to the push fit connector at the front of the equipment Leave the CO2 regulator closed 3 Alterna...

Page 16: ...er Open the mains water supply Check the water connection for leaks 3 Connect the equipment to the mains power supply 4 Press the Ambient water button and dispense 1 L of water to flush the filter The...

Page 17: ...cartridge 4 Remove the filter Brita C1000 cartridge and replace with the Service Cartridge 4 5 Place a container under the discharge Press the key still chilled water button until the water turns blu...

Page 18: ...Sparking water The pump will start and fill the carbonator 9 When the pump stops press button 1 sparkling water and dispense 500 ml of water turn the injector lever to water 10 Allow 30 minutes for th...

Page 19: ...e its effectiveness a simple test is to smell for the Ozone The equipment is built in a hygienically germ free production facility To ensure that the hygie ne remains as intended make sure that cleani...

Page 20: ...utton is pressed the display will light Enable Tones PT Tones ON ON or OFF ECO Reset KG PT CO2 saving counter Press T1 and T2 together to reset Power Ozone PT 00 Ozone generator Off 01 Ozone generator...

Page 21: ...is absolutely necessary to ensure correct operation The filter must be replaced at its rated capacity Regular maintenance such as replacement of seals in use of CO2 systems and visual in spections sho...

Page 22: ...spense nozzle Check the water and CO2 supplies are secure Clean the outside of the unit with a damp cloth to prevent accidental dispense press the right button 1 before cleaning for 5 seconds to lock...

Page 23: ...em fan operate Dispense area Aerator disinfected or replaced as nesecary Dispense area cleaned and disinfected Drip tray Drip tray emptied cleaned and disinfected Overflow functionality of drip tray c...

Page 24: ...e options Inlet water temperature Water outlet temperature Operating temperature room Temp Storage temperature Humidity 4 C 6 C 8 C 5 C to 25 C 4 C 6 C 8 C 10 C to 32 C 2 C to 35 C 35 75 Pressure rati...

Page 25: ...s bacteria menti oned should not be in the water supply The filter will remove them if they are 10 3 CO2 connection There are two options for supplying CO2 to the equipment IQ3 CO2 disposable bottle s...

Page 26: ...the bottle since there are different bottle forms Make sure the pressure regulating valve is closed and attach the to the bottle Fit the 8 mm hose on the lower con nection at the pressure regulating v...

Page 27: ...not fitted correctly There is a leak in the system Check the water filter Turn OFF the water supply and call technician The Sparkling water dis pense is not sparkling CO2 Bottle is empty Replace CO2...

Page 28: ...TTINGS RELEASE CO2 PRESSURE FROM THE CABORNATOR BY THE SAFETY VALVE 12 2 Wiring Diagram SONDA FRIGO CARBONATOR LEVEL Aux k CO2 Count 1 Switch Led F Boiler P COOL PROBE PROBES SONDE LIVELLO PRESSURE SE...

Page 29: ...when applying for national safety certification of electrical products in the various member countries of IECEE Also it is now widely used among business partners in international trade for the detec...

Page 30: ...ther industries organiza tions and associations We are a member of the Association AQUA ITALIA Water production plants for water intended for drinking purposes municipalities consor tia etc using the...

Page 31: ...appliances Safety Part 1 General requirements EN 60335 1 2002 A1 2004 A2 2006 A11 2004 A12 2006 A13 2008 Safety of household and electrical applian ces Part 2 24 Particular requirements for refrigerat...

Page 32: ...Notes 32...

Page 33: ...Notes 33...

Page 34: ...Notes 34...

Page 35: ...Notes 35...

Page 36: ...copyright engl version 2 09 12...

Reviews: