Technical Data
2005/06/10
58 / 60
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
16
Technical Data
Performance table
EcoTouch DS 5027 Ai, DS 5027_Ai_NC und DS 5027_Ai_RC, with R410A, with A-class Pump
DS
5008.5Ai_A
DS
5010.5Ai_A
DS
5012.5Ai_A
DS
5014.5Ai_A
DS
5017.5Ai_A
DS
5020.5Ai_A
DS
5023.5Ai_A
DS
5027.5Ai_A
Groundwater source heating
Performance table W10/W35, kW
1.2/8.0
1.5/9.8
1.9/12.3
2.1/13.9
2.6/18.0
3.1/19.9
3.7/23.1
4.2/26.3
Performance factor W10/W35 (EN 14511)
6.50
6.80
6.68
6.89
6.96
6.38
6.14
6.00
Power input/output. W10/6//B8/4//W35, kW
1)
1.2/7.6
1.5/9.3
1.9/11.7
2.1/13.1
2.6/16.9
3.2/19.0
3.7/22.0
4.2/25.0
Performance factor W10//B8/4//W35
1)
6.20
6.40
6.30
6.45
6.50
6.00
5.90
5.70
Groundwater flow, m³/h (∆t=3K)
1)
1.9
2.4
3.0
3.4
4.3
4.8
5.6
6.3
Groundwater flow, minimum m³/h
2) 1)
1.0
1.2
1.5
1.7
2.1
2.4
2.8
3.2
Heating water flow, m³/h (∆t=5K)
1)
1.4
1.7
2.1
2.4
3.1
3.4
4.0
4.5
Ground source heating
Power input/output. B0/W35, kW
1.2/5.9
1.5/7.3
1.9/9.2
2.1/10.3
2.6/13.3
3.2/15.0
3.6/17.4
4.1/19.7
Leistungszahl bei B0/W35 nach EN 14511
4.70
4.90
5.00
4.91
5.03
4.70
4.80
4.80
Heat source flow
4)
, m³/h (∆t=3K)
1.5
1.8
2.3
2.6
3.4
3.7
4.4
4.9
Heating water flow, m³/h (∆t=5K)
1.0
1.2
1.6
1.8
2.3
2.6
3.0
3.4
Max. power input heat source pump, W
70
5)
130
5)
Max. power input heat pump, W
70
5)
130
5)
Operating limit
B-5/W50 B0/W55 B5/W63 W10/W63
Compressor
Vollhermetic-Scroll
Sound power level (EN9614-2), dB(A)
46,5
47,0
48,0
49,0
48,0
49,5
51,5
50,0
Electrical data 3x400 V, 50 Hz
(Type 1x230 V, 50 Hz)
Unreduced starting current, A
26
(58)
38
(67)
46
(98)
43
(128)
51.5
(115.5)
64
75
101
Starting current with soft start, A
13
(45)
19
(45)
23
(45)
22
(45)
26
(45)
32
38
51
Max. operating current, A
5.5
(16.0)
6.0
(16.0)
7.0
(22.0)
8.0
(26.0)
10.3
(31.0)
11.8
15.0
15.0
Main fuse on site (compressor), A
C 16 A
(C 20 A)
C 16 A
(C 20 A)
C 16 A
(C25 A)
C 16 A
(C 32 A)
C 16 A
(C 32 A)
C 16 A
C 20 A
C 20 A
Control fuse on site, A
B 10 A
B 10 A
B 10 A
B 10 A
B 10 A
B 10 A
B 10 A
B 10 A
Electrical resistance heating, kW
6
Max. operating current
(electrical resistance heating) A
8.7 (26.1)
Customer-supplied main fuse
(electrical resistance heating) A
B16A (B32A)
Filling capacities, dimensions, weights, connections
Compr. volume Oil filling (l) Type: ester oil,
ICI Emkarate RL 32-3MAF
1.1
0.7
1.2
1.2
1.2
1.7
1.8
1.8
Refrigerant volume R410A (kg)
2.15
2.15
2.30
2.30
2.10
2.20
2.20
2.30
Minimum volume of the installation room (m
3
)
4.89
4.89
5.23
5.23
4.77
5.00
5.00
5.23
Volume heating side (l)
6.0
6.0
6.0
6.0
7.0
7.0
7.0
7.0
Volume heat source side (l)
5.5
5.5
5.5
5.5
6.0
6.0
6.0
6.0
Weight of device (kg)
163
155
161
163
172
178
178
183
Connections : Heat source / use
flat sealing R 1¼ “a / R 1¼ “a
Dimensions W x H x D,mm
750 x 1470 x 611
1) Groundwater source heating is to be used with intermediate circuit; for solutions, please refer to our product range. Our
performance data are based on this system configuration. 2) At W10/W35 and ∆t=6K.
3) Tolerances as per EN 12900 and EN 14511 apply to the performance data listed above. 4) Heat source (70 % water + 30 %
ethylene glycol). 5) energy class A.
Summary of Contents for EcoTouch DS 5027 Ai
Page 50: ...Connection diagrams 2005 06 10 50 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 51: ...Connection diagrams 2005 06 10 51 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 52: ...Connection diagrams 2005 06 10 52 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 53: ...Connection diagrams 2005 06 10 53 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 54: ...Connection diagrams 2005 06 10 54 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 55: ...Connection diagrams 2005 06 10 55 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 59: ...Technical Data 2005 06 10 59 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...