Installation and connection
2005/06/10
26 / 60
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
7.3
Connection to heat source
The following can be used as heat source:
The ground, by connection to a horizontal geothermal absorber (e.g.
PE-pipe20x2) or a vertical geothermal absorber (geothermal probes).
The groundwater, by connection to a well system, using an accessories
kit available from WATERKOTTE to monitor the flow at heat source side
and separation heat exchanger (heat source side).
The layout of the heat source system must be according to the
WATERKOTTE dimensioning information. .
Refer to the performance table to find the volume flow for the corre-
sponding heat pump.
The heat source connections (1¼“) feature an external pipe thread for
flat-sealing connections with union nut and insert.
The heat pump is equipped with a 12 l pressure expansion tank.
A circulation class A pump is installed at heat source side.
Heat pump type /
circulation pump
EcoTouch
DS 5008.5 bis DS 5014.5
EcoTouch
DS 5017.5 bis DS 5027.5
heat source, circula-
tion class A pump
Stratos Para 25/1-7 T13
(Art. Nr. Z20382)
Stratos Para 25/1-8 T13
(Art. Nr. Z20383)
The heat pump also includes the following:
One air separator
One safety fitting (air diverter / filling pressure gauge / safety valve)
To prevent formation of condensation, the heat source lines inside the
house must have diffusion tight insulation.
In case of water glycol systems, it is not permitted to use steel pipes
and other steel components in the water circuit. Use stainless steel,
copper, brass or plastic - such as PE - for instance.
Steel pipes and other steel components should also be avoided in
groundwater systems.
Summary of Contents for EcoTouch DS 5027 Ai
Page 50: ...Connection diagrams 2005 06 10 50 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 51: ...Connection diagrams 2005 06 10 51 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 52: ...Connection diagrams 2005 06 10 52 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 53: ...Connection diagrams 2005 06 10 53 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 54: ...Connection diagrams 2005 06 10 54 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 55: ...Connection diagrams 2005 06 10 55 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 59: ...Technical Data 2005 06 10 59 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...