4.3
Electrical equipment
The electrical connections are made via the internal terminal (on the con-
struction profile). The implementation of the electrical cable is carried by the
rear wall (with the strain relief).
The internal terminal connects the entire sensor, all queries, all relay out-
puts, digital circuit, the compressor and the electrical heating element. The
WATERKOTTE WWPR-controller is supplied with a control panel mounted
on the 24 V AC transformer.
4.3.1
Electrical resistance heating
Located in the heating flow, power 6 kW. Used to support initial heating in
the winter and during the standby function.
4.4
Domestic hot water heating system
Consisting of: heating circulation pump (speed-controlled / energy class A),
air separator with automat. air diverter, filling pressure gauge, overpressure
safety valve, filling valve, large expansion tank, 12 or 18 liters; connections
for heating flow and return are fitted externally to facilitate installation in the
rear panel frame.
4.4.1
Heatsource
Consisting of: heating circulation pump (speed-controlled / energy class A),
air separator with automat. air diverter, filling pressure gauge, overpressure
safety valve, large expansion tank 12 liters, connections for heating flow
and return are fitted externally to facilitate installation in the rear panel
frame.
4.4.2
Electronic heat pump control
The heat pump control (control panel is pictured) is included in the delivery
scope of the WATERKOTTE heat pump.
Use in other than WATERKOTTE heat pumps will void any warranty claim.
The control is used to control and monitor heating systems that are operat-
ed with WATERKOTTE compact heat pumps according to technical guide-
lines of WATERKOTTE Wärmepumpen GmbH.
The following tasks are performed: everything to do with regulation (de-
pending on the external temperature with pilot room guidance), control,
monitoring, self-diagnosis, saving of data in cases of breakdown.
WATERKOTTE explicitly states that function warranty will become void if
used on systems not approved by WATERKOTTE. Any liability for con-
sequential damages due to incorrect function within these systems shall be
explicitly excluded.
Summary of Contents for EcoTouch DS 5027 Ai
Page 50: ...Connection diagrams 2005 06 10 50 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 51: ...Connection diagrams 2005 06 10 51 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 52: ...Connection diagrams 2005 06 10 52 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 53: ...Connection diagrams 2005 06 10 53 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 54: ...Connection diagrams 2005 06 10 54 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 55: ...Connection diagrams 2005 06 10 55 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 59: ...Technical Data 2005 06 10 59 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...