Installation of heat pump and tank
12.11.2015
22 / 60
Z21826
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes
7.2.1
Dismantlement/ Assembly of the heat pump (service event)
When it is necessary to dismantle the heat pump you are able to split the upper
and the lower part.
Procedure:
Switch the heat pump currentless (fuse box)
Close the hydraulical circuit and void the drinking water storage
Free the connecting hose to the storage (up and low), see the pictures
Figure 6: Storage connectings (left: storage connecting top with vent valve)
Separate the electrical connection to the display and the temperature sensor
Free the 16 lens head screws at the montage strives (see at the picture)
Lift the storage module and put it on a plane area
Figure 7: Rear safed with lens-head screws (Pos. 1)
Note: For lifting the storage module you need sveral people.
The module weights about 59 kg.
Summary of Contents for EcoTouch Ai1 Geo
Page 57: ...Technical data 12 11 2015 57 60 Z21826 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 58: ...Technical data 12 11 2015 58 60 Z21826 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 59: ...Technical data 12 11 2015 59 60 Z21826 Copyright 2013 by WATERKOTTE GmbH Subject to changes...