CONTROL VALVE SPECIFICATIONS
SERVICE FLOW RATE & PRESSURE LOSS
(valve only, including bypass valve, but not
including mineral, etc.)
27 gpm (102.2 lpm) @ 15 psi (103 kPa)
∆
∆
∆
∆
P
BACKWASH FLOW RATE & PRESSURE LOSS
(whole conditioner...including bypass valve)
27 gpm (102.2 lpm) @ 25 psi (172 kPa)
∆
∆
∆
∆
P
MINIMUM & MAXIMUM OPERATING
PRESSURE
20 psi (138 kPa) - 125 psi ( 862 kPa)
MINIMUM & MAXIMUM OPERATING
TEMPERATURE
40∞F (4∞C) -110∞F (38∞C)
CURRENT DRAW & VOLTAGE
0.5 amperes 110 volts
REGENERANT TANK REFILL RATE
0.5 gpm (1.9 lpm)
INLET / OUTLET FITTING TYPES
(a) 1" NPT elbow
(b) 3/4" & 1" PVC solvent weld socket
(c) 1" straight brass sweat fitting
(d) 3/4" straight brass sweat fitting
DISTRIBUTOR TUBE
1.05" O.D. (3/4" U.S. PVC Pipe Size)
TANK THREAD
2Ω" - 8 NPSM
PC BOARD MEMORY
Nonvolatile EEPROM
(electrically erasable programmable read only
memory)
COMPATIBLE REGENERANTS
sodium chloride, potassium chloride, potassium
permanganate, sodium hydroxide, hydrochloric acid
COMPATIBLE CHEMICALS
sodium bisulfite, sodium hydrosulfite, chlorine,
chloramines
During operation, the normal user displays such as time of day, gallons or days remaining before regeneration
(optional), and salt warning (optional), are shown. Each of these can be viewed by pressing NEXT to scroll through
them. When moving through any displays or programming, if no buttons are pressed within five minutes, the display
returns to normal operating displays. Any changes made prior to the five minute time out are incorporated.
To quickly exit any Programming, Installer Settings, etc., press SET CLOCK. Any changes made prior to the exit
are incorporated.
If desired, two regenerations within 24 hours are possible with a return to the preset program. To do a double
regeneration if the control valve is factory set to “NORMAL” or “ on 0” (see Step 9S under SOFTENER
SYSTEM SETUP):
1. Press the “REGEN” button once. REGEN TODAY will flash on the display.
2. Press and hold the “REGEN” button for three seconds until a regeneration begins.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset
regeneration time.
GENERAL INSTRUCTIONS