page 10
NOTE: What follows assumes that AUTO is set for regeneration mode in Step 8S,
meaning gallons are automatically calculated.
STEP 1I - Press NEXT and
∆
simultaneously for 3 seconds.
STEP 2I – Hardness: Set the amount of hardness in grains per gallon (default 20)
using the or
∆
buttons. The allowable range is from 1 to 150 in 1 grain
increments. Note: Increase the grains per gallon if soluble iron is present. This
display will show “–nA–” if “FILTER” is selected or if “AUTO” is not selected previ-
ously. Press NEXT to go to step 3I. Press REGEN if you want to exit.
STEP 3I – Day Override: When gallon capacity is set to off, this sets the number
of days between regenerations. When gallon capacity is factory set to AUTO or to
any number, this sets the maximum number of days between regenerations. If this
is set to “oFF”, regeneration initiation is based solely on gallons used. If any
number is set (allowable range from 1 to 28), a regeneration initiation will be called
for on that day even if sufficient number of gallons were not used to call for a
regeneration. Set Day Override using
or
∆
buttons (14 recommended):
•
set number of days between regeneration (1 to 28, default 14); or
•
set to “oFF”.
Press NEXT to go to step 4I. Press REGEN if you need to return to previous step.
STEP 4I – Next Regeneration Time (hour): Set the hour of day for regeneration
using or
∆
buttons. AM/PM toggles after 12.
The default time is 2:00 a.m. (recommended).
This display will show “REGEN on 0 GAL” if immediate regeneration was factory
set. Press NEXT to go to step 5I. Press REGEN if you need to return to previous
step.
STEP 5I – Next Regeneration Time (minutes): Set the minutes using or
∆
buttons. This display will not be shown if “on 0” is selected in step 9S.
Press NEXT to exit Installer Settings. Press REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN” button
for three seconds. The system will begin to regenerate immediately. The control
may be manually stepped through the regeneration cycles by pressing “REGEN”.
RETURN TO NORMAL MODE
INSTALLER SETTINGS
STEP 1I
ß
STEP 2I
STEP 3I
STEP 4I
ß
STEP 5I
ß
ß
ß
TIME OF DAY
Time of day should only need to be set after extended power outages or when
daylight saving time begins or ends. If an extended power outage occurs, the time of
day will flash on and off indicating that the time should be reset.
STEP 1U – Press SET CLOCK.
STEP 2U - Current Time (hour): Set the hour of the day using or
∆
buttons.
AM/PM toggles after 12. Press NEXT to go to step 3U.
STEP 3U - Current Time (minutes): Set the minutes using
or
∆
buttons. Press
NEXT to exit Set Clock. Press REGEN to return to previous step.
SET TIME OF DAY
STEP 1U
STEP 2U
STEP 3U
ß
ß
ß
RETURN TO
NORMAL MODE