TROUBLESHOOTING PROCEDURES, TIMECLOCK UNITS

 

 

Problem

 

Cause

 

Solution

 

 

 

 

1. Timer does not display time of day

 

a. Transformer unplugged

 

a. Reconnect

 

b. No power at outlet

 

b. Restore power

 

c. Defective transformer

 

c. Replace transformer

 

d. Defective PC board

 

d. Replace PC board

 

 

 

2. Timer does not display correct time of day

 

a. A "switched" outlet may be in use

 

a. Use uninterrupted outlet

 

b. Power outage occurred

 

b. Reset time of day

 

c. Defective PC board

 

c. Replace PC board

 

 

 

3. Unit regenerates at wrong time of day

 

a. Power outage occurred

 

a. Reset time of day

 

b. Time of day not set correctly

 

b. Reset time of day

 

c. Regeneration time set incorrectly

 

c. Reset time of regeneration

 

 

 

 

 

 

 

 

4. E1, E2 or E3 Error Codes displayed.

 

 

E1 - Unable to recognize start of regeneration 

E2 - Unexpected stall

 

E3 - Motor ran too long. It timed out while 

trying to reach the next cycle position or 

trying to reach home position.

 

 

a. Valve has just been serviced

 

a. Press SET HOUR and DOWN for 3 seconds 

or momentarily unplug power from PC board

 

 

b. Piston is obstructed

 

b. Check piston and spacer stack for 

obstruction

 

c. High drive forces on piston

 

c. Replace piston(s) and spacer stack  assembly

 

 

d. Piston not in home position

 

d. Press SET HOUR and DOWN for 3 seconds 

or momentarily unplug power from PC board

 

e. Motor not fully inserted and not engaging 

pinion gear. Motor wires loose or broken. 

Motor failure.

 

 

e. Check motor and wiring. Replace motor if 

necessary.

 

f. Center drive gear reflector dirty or damaged. 

Missing or or broken gear.

 

f. Swap drive gears to have good reflector on 

center gear. Clean drive gear. Replace gear.

 

g. Drive bracket incorrectly aligned on 

backplate

 

 

g. Reset drive bracket. Be sure wires are clear.

 

h. PC board is damaged or defective

 

h. Replace PC board

 

i. PC board not seated correctly on drive 

bracket

 

 

i. Reinstall  PC board

 

 

 

 

 

 

5. Valve stalled in regeneration

 

a. Motor not operating

 

a. Replace motor

 

b. No power at outlet

 

b. Restore power

 

c. Defective transformer

 

c. Replace transformer

 

d. Defective PC board

 

d. Replace PC board

 

e. Broken drive gear or drive cap assembly

 

e. Replace gear or drive cap assembly

 

f. Broken piston retainer

 

f. Replace drive cap assembly

 

g. Broken main or regenerant piston

 

g. Replace broken piston

 

 

6. Unit does not regenerate automatically when 

UP and DOWN buttons are pressed and held

 

a. Transformer unplugged

 

a. Check connection at outlet and at PC board

 

b. Broken drive gear or drive cap assembly

 

b. Replace gear or drive cap assembly

 

c. Defective PC board

 

c. Replace PC board

 

 

7. Unit does not regenerate automatically but 

does when UP and DOWN are depressed

 

a. Defective PC board

 

a. Replace PC board

 

b. Programming error

 

b. Check days between regen setting

 

Summary of Contents for Fusion 2

Page 1: ...FT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION...

Page 2: ......

Page 3: ...ingSETHOURand UP simultaneouslyfor3 seconds 2 Adjusttimeof regenerationhourusing the UP or DOWN An arrow points to PM duringp m hours Simultaneously pressSETHOURandDOWNtoreturn tonormal operation MANU...

Page 4: ...ption f Note that an external signaling device like a pressure differential switch can be used to trigger the backwashing of a filter An explanation of this is at the end of SYSTEM SETUP g Use the mai...

Page 5: ...e five minute time out are incorporated To quickly exit SOFTENER SETUP or INSTALLER SETTINGS press SET HOUR and DOWN Any changes made prior to the exit are incorporated SYSTEM SETUP STEP 1SS STEP 2SS...

Page 6: ...o choices If a differential switch is not installed the settings in this display are ignored Press SET HOUR to exit SYSTEM SETUP NOTE The two terminals at A if connected to an external pressure differ...

Page 7: ...SET HOUR UP buttons simultaneously for 3 seconds and release Set Regeneration Time STEP 2I7 STEP 3I7 STEP 4I7 STEP 2I7 Regeneration Time Set the clock to the hour the regeneration should occur by usi...

Page 8: ...ing and an arrow will also point to Regen The system will run through the steps automatically and will reset itself to provide treated water when the regeneration is completed Manual Regeneration Some...

Page 9: ...g steadily to the drain without the presence of air press the UP button This will advance the valve to the regenerant draw position C2 Fully open the inlet bypass valve handle the diagnostic mode Figu...

Page 10: ...momentarily unplug power from PC board e Motor not fully inserted and not engaging pinion gear Motor wires loose or broken Motor failure e Checkmotor and wiring Replace motor if necessary f Centerdriv...

Page 11: ...PAGE LEFT BLANK INTENTIONALLY...

Page 12: ...WATERITE INC Winnipeg Manitoba Canada www waterite com...

Reviews: