QUICK REFERENCE  INFORMATION

 

 

 

GENERAL OPERATION

 

When the system is operating one of 

two displays will be shown: time of 

day or days until the next regenera- 

tion. Pressing UP or DOWN will 

toggle between the two choices.

 

 

 

TO SET TIME OF DAY

 

In the event of a power outage, time of day 

needs to be reset. All other information will 

be stored in memory no matter how long 

the power outage. Please complete the 

steps as shown to the right. To access this 

mode, press SET HOUR.

 

 

 

TO SET TIME OF 

REGENERATION

 

For initial set-up or to make adjustments, 

please complete the steps as shown to 

the right. Access this mode by pressing 

SET HOUR and UP simultaneously for 3 

seconds.

 

 

Arrow will point to Regen if a 

regeneration is expected 

“Tonight.”

 

 

 

 

                    

 

 

 

 

 

 

 

 

 

1.  Accessed by pressing SET 

HOUR.

 

2.  Adjust to the nearest hour using 

UP or DOWN. An arrow points to 

PM during p.m. hours.

 

3.  Press SET HOUR to complete 

and return to normal operation.

 

 

 

1.  Accessed by pressing SET HOUR and 

UP simultaneously for 3 seconds.

 

2.  Adjust time of regeneration hour using 

the UP or DOWN. An arrow points to 

PM during p.m. hours. Simultaneously 

press SET HOUR and DOWN to return 

to normal operation.

 

 

MANUAL REGENERATION

 

NOTE: 

For softeners, if brine tank does not contain salt, fill 

with salt and wait at least 2 hours before regeneration.

 

If you need to initiate a manual regeneration, either 

immediately, or tonight at the preprogrammed time (typically 

2 a.m.), complete the following steps.

 

For Immediate Regeneration:

 

Press and hold UP and DOWN simultaneously until valve 

motor starts (typically 3 seconds).

 

For Regeneration Tonight:

 

Press and release UP and DOWN simultaneously (notice that 

arrow points to Regen).

 

 

 

 

 

Arrow will point to Regen if a 

regeneration is expected “Tonight.”

 

 

 

 

 

ERROR CODES: 

If the display shows “E1,” “E2” or “E3” (for error), 

call a service technician.

 

 

To 

shut off water 

to the system, please position arrow handles as shown in the 

bypass operation 

diagram below. 

If your valve doesn’t look like the diagram below, contact your dealer.

 

 

NORMAL O P E R AT I O N  

BYPASS O P E R AT I O N

 

Treated 

Water

 

Supply Water

 

Supply Water

 

Supply Water

 

 

 

_______       

     

or          

 

Summary of Contents for Fusion 2

Page 1: ...FT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION...

Page 2: ......

Page 3: ...ingSETHOURand UP simultaneouslyfor3 seconds 2 Adjusttimeof regenerationhourusing the UP or DOWN An arrow points to PM duringp m hours Simultaneously pressSETHOURandDOWNtoreturn tonormal operation MANU...

Page 4: ...ption f Note that an external signaling device like a pressure differential switch can be used to trigger the backwashing of a filter An explanation of this is at the end of SYSTEM SETUP g Use the mai...

Page 5: ...e five minute time out are incorporated To quickly exit SOFTENER SETUP or INSTALLER SETTINGS press SET HOUR and DOWN Any changes made prior to the exit are incorporated SYSTEM SETUP STEP 1SS STEP 2SS...

Page 6: ...o choices If a differential switch is not installed the settings in this display are ignored Press SET HOUR to exit SYSTEM SETUP NOTE The two terminals at A if connected to an external pressure differ...

Page 7: ...SET HOUR UP buttons simultaneously for 3 seconds and release Set Regeneration Time STEP 2I7 STEP 3I7 STEP 4I7 STEP 2I7 Regeneration Time Set the clock to the hour the regeneration should occur by usi...

Page 8: ...ing and an arrow will also point to Regen The system will run through the steps automatically and will reset itself to provide treated water when the regeneration is completed Manual Regeneration Some...

Page 9: ...g steadily to the drain without the presence of air press the UP button This will advance the valve to the regenerant draw position C2 Fully open the inlet bypass valve handle the diagnostic mode Figu...

Page 10: ...momentarily unplug power from PC board e Motor not fully inserted and not engaging pinion gear Motor wires loose or broken Motor failure e Checkmotor and wiring Replace motor if necessary f Centerdriv...

Page 11: ...PAGE LEFT BLANK INTENTIONALLY...

Page 12: ...WATERITE INC Winnipeg Manitoba Canada www waterite com...

Reviews: