background image

5

 

 

INSTALLER SETTINGS

 

 

 

 

 STEP 1ID 

 

 

 

 

 

 STEP 2ID 

 

 

 

 

 

 

 STEP 3ID 

 

 

 

 

REGENERATION TIME & DAYS BETWEEN (1-99 day option)

 

STEP 1ID 

– From normal mode, press SET HOUR + UP buttons simultaneously for 3

 

seconds and release.

 

 

 

Set Regeneration Time

 

STEP 2ID 

– Regeneration Time: Set the clock to the hour the regeneration should occur 

by using the UP or DOWN buttons.  An arrow points to PM after 12.

 

Press SET HOUR to go to STEP 3ID.

 

 

 

 

Set Days between Regenerations (1-99)

 

(The choice of 1-99 days or 1-7 days is set in Step   4SS)

 

STEP 3ID 

– Days To Regen: Set the number of days between regenerations. 

The allowable range is 1 to 99.

 

Press SET HOUR to exit.

 

 

 

 

 

 

 

STEP 1I7      

 
 
 
 

REGENERATION TIME & DAYS BETWEEN (1-7 day option)

 

(The choice of 1-99 days or 1-7 days is set in Step   4SS)

 

STEP 1I7 

– From normal mode, press SET HOUR + UP buttons simultaneously for 

3 seconds and release

.

 

 

Set Regeneration Time

 

 STEP 2I7 

 

 

 

 

 

 

 

 

 STEP 3I7 

 

 

 

 

 

 

 

 

 STEP 4I7 

 

 

 

 

STEP 2I7 

– Regeneration Time: Set the clock to the hour the regeneration should occur 

by using the UP or DOWN buttons.  An arrow points to PM after 12.

 

Press SET HOUR to go to STEP 3I7.

 

 

 

 

 

Choose Days for Regeneration (1-7 day option)

 

STEP 3I7 

– 

ACCESS DAY OF THE WEEK CODES 

by

 

using the UP or DOWN buttons. 

Press SET HOUR to go to STEP 4I7.

 

 

 

 

STEP 4I7 

– 

d1

, Sunday, will be 

displayed. (See chart at right for day 

codes).

 

To regenerate on Sunday use the UP or DOWN 

button until the arrow points to Regen.

 

To SKIP Sunday, use UP or DOWN to remove arrow from Regen. 

Press SET HOUR to go to 

d2

, Monday.

 

Repeat procedure of using UP or DOWN to select or skip REGEN and using SET HOUR 

to advance to next day.

 

After 

d7 

the display will return to the normal operating  display.

 

 

 

 

 

DISPLAY

 

DAY OF WEEK

 

d1

 

Sunday

 

d2

 

Monday

 

d3

 

Tuesday

 

d4

 

Wednesday

 

d5

 

Thursday

 

d6

 

Friday

 

d7

 

Saturday

 

 

Summary of Contents for Fusion 2

Page 1: ...FT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION...

Page 2: ......

Page 3: ...ingSETHOURand UP simultaneouslyfor3 seconds 2 Adjusttimeof regenerationhourusing the UP or DOWN An arrow points to PM duringp m hours Simultaneously pressSETHOURandDOWNtoreturn tonormal operation MANU...

Page 4: ...ption f Note that an external signaling device like a pressure differential switch can be used to trigger the backwashing of a filter An explanation of this is at the end of SYSTEM SETUP g Use the mai...

Page 5: ...e five minute time out are incorporated To quickly exit SOFTENER SETUP or INSTALLER SETTINGS press SET HOUR and DOWN Any changes made prior to the exit are incorporated SYSTEM SETUP STEP 1SS STEP 2SS...

Page 6: ...o choices If a differential switch is not installed the settings in this display are ignored Press SET HOUR to exit SYSTEM SETUP NOTE The two terminals at A if connected to an external pressure differ...

Page 7: ...SET HOUR UP buttons simultaneously for 3 seconds and release Set Regeneration Time STEP 2I7 STEP 3I7 STEP 4I7 STEP 2I7 Regeneration Time Set the clock to the hour the regeneration should occur by usi...

Page 8: ...ing and an arrow will also point to Regen The system will run through the steps automatically and will reset itself to provide treated water when the regeneration is completed Manual Regeneration Some...

Page 9: ...g steadily to the drain without the presence of air press the UP button This will advance the valve to the regenerant draw position C2 Fully open the inlet bypass valve handle the diagnostic mode Figu...

Page 10: ...momentarily unplug power from PC board e Motor not fully inserted and not engaging pinion gear Motor wires loose or broken Motor failure e Checkmotor and wiring Replace motor if necessary f Centerdriv...

Page 11: ...PAGE LEFT BLANK INTENTIONALLY...

Page 12: ...WATERITE INC Winnipeg Manitoba Canada www waterite com...

Reviews: