Lamp Timer Operation (for models prior to February 2011 ONLY): 

The annual lamp change reminder timer will run for approximately one full year. 
At the end of this one-year period, the lamp change timer will flash and the 
buzzer will sound.  The flashing 

red

  LED indicates that the timer function has 

entered its 28-day grace period. Pushing the timer button during this grace period 
will silence the alarm buzzer for a seven-day period but the 

red

 

LED will continue 

to flash.  The buzzer reset can be activated a maximum of four times during the 
28-day grace period.  Under no circumstances does the grace period exceed 28-
days.  At the expiry of the grace period the UV power source indicates the lamp 
change alarm by illuminating the

 

red

  timer LED continuously and sounding the 

buzzer.  

Note

: The UV lamp is not shut down in this alarm mode and the solenoid 

valve drive is not disabled. 

 

Time Remaining (for models prior to February 2011 ONLY): 

When the lamp change reminder timer is not in the 28-day grace period or lamp 
change alarm mode, the number of months of lamp life remaining can be 
determined by pressing the timer push button and counting the number of times 
the

 

red 

timer LED flashes.   See “Resetting of Lamp Change Timer” in the 

Operating and Maintenance section following. 
 

 

OPERATING AND MAINTENANCE

 

Your Excelight UV System is “ON” continuously during normal operation.  After 
periods of not using your water supply exceeding two to three days, it is 
recommended to open all faucets and flush your plumbing system for one to two 
minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Excelight EL411AK

Page 1: ...r Excelight UV system models EL411AK EL720AK and EL1129AK IMPORTANT READ AND UNDERSTAND TERMS OF THE MANUFACTURER S WARRANTY ON PAGE 15 OF THIS MANUAL FILL OUT THE WARRANTY REGISTRATION CARD WITH THE...

Page 2: ...OUTSIDE THE DISINFECTION CHAMBER EXPOSURE TO UV LIGHT CAN RESULT IN SERIOUS INJURY AND EXTREME BURNING OF THE SKIN AND EYES Excelight UV disinfection systems are equipped with both visual and audible...

Page 3: ...professionally tested for dissolved mineral content turbidly and microbiological activity Your UV disinfection system requires clean clear water for optimum performance You should only operate your u...

Page 4: ...ding stud on the end of the reactor vessel 2 Excelight UV disinfection devices are designed to be installed on the cold water line only 3 Install the Excelight UV disinfection system indoors in a prot...

Page 5: ...e figure 1 1 Shut off the main water supply valve 2 Mount the unit to the wall in the selected location using the brackets and screws provided 3 Mount the power supply beside or above the reactor vess...

Page 6: ...Figure 2 WARNING If soldering copper pipes do not allow heat near plastic or nylon threads or fittings 7 Remove the electrical end caps Note that the quartz sleeve has not been factory installed Figu...

Page 7: ...Ensure the valves on either side of the disinfection unit are closed Open the main supply valve Open the valve on the discharge side of the disinfection unit Open the valve slowly on the feed side of...

Page 8: ...re attaching 3 Verify that the UV system is connected to the AC power voltage and operating properly 4 Turn the valves to the open position and let the water flow 5 Open all faucets fixtures and appl...

Page 9: ...n NOTE The UV power source is designed to shut down if the AC input voltage is outside its operating limits When a lamp failure alarm is activated you should unplug the unit from the AC power source w...

Page 10: ...wer source indicates the lamp change alarm by illuminating the red timer LED continuously and sounding the buzzer Note The UV lamp is not shut down in this alarm mode and the solenoid valve drive is n...

Page 11: ...p the lamp into the quartz as both are easily broken 3 Carefully slide the lamp out of the quartz sleeve and discard 4 Loosen and remove both end caps Roll back the o rings at both ends and remove Car...

Page 12: ...power source reset SYSTEM REPLACEMENT PARTS EXCELIGHT System Replacement UV Lamps Standard 4 pin 9000 rated hours Excelight EL411A UV Lamp 20W 450mm EL411L Excelight EL720A UV Lamp 32W 645mm EL720L Ex...

Page 13: ...Bacillus subtillis vegetative 11 000 Penicillum digitatum olive 88 000 Bacillus subtillis spore 58 000 Penicillum expensum olive 22 000 Clostridium tetani 22 000 Penicillum roqueforti green 26 400 Co...

Page 14: ...cus lactis 8 800 Common yeast cake 13 200 Streptococcus viridans 3 800 Saccharomyces ellipsoideus 13 200 Vibrio cholerae 6 500 Saccharomyces sp 17 600 The approximate dosages flow rate for Excelight u...

Page 15: ...the original one 1 year warranty period This warranty is also subject to the conditions and limitations outlined under the heading General Conditions and Limitations below Warranty for Replacement Lam...

Page 16: ...16 Waterite Inc 204 786 1604 204 783 1599 fax waterite waterite com www waterite com...

Reviews: