MINIMUM CLEARANCES TO COMBUSTIBLES
From the front of the stove
48” - 1200mm
From back of stove
24” - 600mm
From the side of stove
19” - 480mm
From corner installation
12” - 300mm
From the flue pipe
23” - 580mm
Mantle clearance
26 1/2” - 675mm
Side trim, which extends
less than 2” from the face
of the fireplace
10” - 250mm
MANTLE & TRIM CLEARANCES
If the stove is to be installed using the rear exit
option then the UL/ULC listed Optional rear heat
shield must be fitted together with a listed pipe
shield fitted from the heat shield to the back wall on
the underside of the chimney connector.
(See horizontal installation).
Rear Exit
From back of stove
12” - 300mm
From side of stove
19” - 480mm
plate (item 72) and the double top flue spigot shield
(item 74) over the tie bolts and tighten the whole
assembly together using the four
1/4
” nuts provided.
When the Waterford listed heat shields are used
together with a listed pipe shield using the top exit
option the clearances may be reduced to 9
1/2
”.
(Pipe shield and heat shields are not supplied as
standard.
4
REDUCED CLEARANCES
Under certain conditions the minimum clearances
may be reduced by means of:
(a)
Listed Waterford rear heat shield assembly
installed in accordance with the manufactur
ers instructions.
(b)
Shields constructed in accordance with
NFPA211 (USA) Can3-B365 installation
code for solid fuel fired appliances.
(c)
Fitting the listed Waterford Heat Shield and
chimney connector pipe shield.
REAR HEAT SHIELD
If the stove e is to be connected to a top flue exit
then the rear heat shield assembly must be fitted as
follows: Screw the four 4” x 1/4” heat shield tie bolts
(item 69) to the back plate (item 23). Fit the four 2”
spacers (item 70) over the heat shield tie bolts. Fit
the inner heat shield (item 75) complete with rear
heat shield blanking plate (item 72) onto the four
heat shield tie bolts. Now fit the four 1” spacers
(item 71) over the tie bolts and fit the outer heat
shield (item 76) complete with heat shield blanking
1 inch spacer
Fitting of listed pipe
shield.
Pipe shield and chimney
connector are not sup-
plied as standard with
the stove
.
Fitting of rear heat
shield