2

Button appearance and position may be different than actual valve

Cycle times, sequences, and settings in this guide are only examples of how your system may be programmed.  
Actual settings are determined by the manufacturer. Please contact them if more information is needed.

Important button sequences to note:

1. 

UNLOCK VALVE SETTINGS:

 Push buttons in the following order: 

NEXT

+

CLOCK

. This will allow user to change  

    manufacturer’s settings. When finished, lock settings by pushing the same sequence.
2. 

CLEAR ERROR ON SCREEN:

 Push and hold 

NEXT

 and 

REGEN

 for three seconds.

3. 

CLEAR SERVICE ALARM:

 If service alarm is triggered, push and hold 

+

 and 

 simultaneously for three seconds to reset to      

    original set points. This will reset both gallon and year alarms.

General Operation Screens

Set Time Screens

Typical Regen Screens

Pressing 

NEXT

 will toggle between one of five displays. Press 

REGEN

 to set a regeneration to occur tonight.

Accessed by pressing 

CLOCK

.

Only visible when unit is in regeneration.

DAYS TO A REGEN

GPM

3

8

CAPACITY REMAINING

GPM

GAL

1600

8

FLOW RATE

GPM

8.0

TIME OF DAY

MON

GPM

2:40

8

PM

“GPM” and flow rate 

flash while turbine is 

rotating

Return to general display

Return to general display

“REGEN TODAY” 

will alternate with the 

current screen header 

if a regen is expected 

tonight

Displays current time.

Unit defaults to this screen 

after a reset.

Displays a unit’s remaining capacity.

This screen will not display if the unit’s gallons of 

capacity is set to OFF. The unit may run into negative 

capacities and will regenerate two nights in a row if 

it overruns its capacity by the selected percentage.

Displays days remaining until a regen.

This screen will not display if the unit’s day  

override is set to off.

Set hours with + or — buttons.

AM/PM toggles after 12 AM.

Displays time remaining in  

current regeneration cycle

“2” flashes for a second backwash if 

two backwashes are programmed.

Displays time remaining in 

current cycle

If an ozone generator is connected and set to ON, 

the duration of the ozone generation is displayed.

Set minutes with + or — buttons.

AM/PM toggles after 12 AM.

Set current day with + or — buttons.

The default setting is WED.

Displays scrolling dealer name 

and phone number.

To change dealer name and phone 

number, see page 3 or 4.

Displays current flow rate.

“Current Flow Rate” is the amount of  

water currently flowing through, and  

being treated by, the unit. 

555 5555555

DEALER NA

Any one of these chosen  

displays will flash alternately 

with dealer name screen if set.

CURRENT DAY

SET

WED

TIME

MINUTES

SET

TIME

HOUR

SET

2:00

2:35

AM

AM

MIN

BACKWASH REMAINING

2

3:30

GENERATOR ON

53:45

Summary of Contents for Impression

Page 1: ...Master Programming Manual for Impression Impression Plus and Impression Twin Models Effective January 2018...

Page 2: ...REGEN TODAY will alternate with the current screen header if a regen is expected tonight Displays current time Unit defaults to this screen after a reset Displays a unit s remaining capacity This scre...

Page 3: ...t backlight operation with or buttons Default setting is ON OFF will turn display backlight off after 5 minutes of keypad inactivity Scrolling contact phone number screen Set phone number by using the...

Page 4: ...or one position to the right Continuing to press the NEXT button will advance to the Contact Name Display Contact name screen Set contact name by using the or buttons Pushing the NEXT button will adva...

Page 5: ...gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen point with or buttons If unit s capacity...

Page 6: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Page 7: ...have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determine a regen and...

Page 8: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Page 9: ...ault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DEL...

Page 10: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Page 11: ...lay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by...

Page 12: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Viewed in 1 0T Mode only 1 indicates most recent tank transfer A i...

Page 13: ...tected or will be the average values measured during generator period of operation AAA Generator current draw in mA VV V Generator voltage in VDC Viewed only if SERVICE OEM is set to OZONE ON Displays...

Page 14: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Page 15: ...15 Notes...