background image

14

SOFTWARE VERSION

XXX

xx

TOTAL GALLONS

0

X1K

TOTAL DAYS

970

TOTAL REGENS

190

1

ERROR LOG

101

1

4

5

2

3

Second Level History Screens   

 

 

 

 

 

       

Accessed by pressing 

+

 and 

 simultaneously for three seconds. 

Once screen changes, press 

+

 and 

 simultaneously again for three seconds.

Non-resettable history.

Displays software version.

Displays total gallons used 

by Meter 1 since startup.

Displays total days unit has 

been in service.

Displays total regens since startup.

Displays last ten valve errors that occurred. 

Scroll through with + or — buttons.

Return to general display

Error Code

Error Code Description

101

UNABLE TO START:

Valve not sensing valve movement with motor energized.

102

MOTOR STALLED:

Valve unable to find next cycle position (stalled).

103

MOTOR RAN TOO LONG: Valve unable to find next cycle position.

104

VALVE HOMING:

Valve unable to find Home position.

106

MAV 1 RAN TOO LONG:

MAV 1 motor ran too long. Unable to find proper park position.

107

MAV 1 STALLED:

MAV 1 motor ran too short. Unable to find proper park position (stalled).

109

INVALID MOTOR STATE:

Control can no longer operate properly due to detection of an invalid motor state. 

116

MAV 2 RAN TOO LONG:

MAV 2 motor ran too long. Unable to find proper park position. 

117

MAV 2 STALLED:

MAV 2 motor ran too short (stalled). Unable to find proper park position.

201

INVALID REGEN STEP:

Control can no longer operate properly due to detection of an invalid  

regeneration cycle step. Internal software issue.

204

LEAK DETECTED

402

POWER DOWN MEMORY: Check sum error for operational data and status section of EEPROM memory  

- specific type of memory error. 

403

PROGRAM MEMORY:

Check sum error for programming section of EEPROM memory 

- specific type of memory error.

404

DIAGNOSTIC MEMORY:

Check sum error for diagnostic section of EEPROM memory  

- specific type of memory error.

405

HISTORY MEMORY:

Check sum error for history section of EEPROM memory  

- specific type of memory error.

406

CONTACT MEMORY:

Check sum error for contact screen section of EEPROM memory  

- specific type of memory error.

407

STATUS RAM MEMORY  

FAILURE:

Control can no longer operate properly due to corrupted data detected in the Operational Data and Status 

Section of RAM memory. Once generated, the Error Mode is not entered nor an error displayed, instead 

previously stored data (<6 hours old) is used to maintain control operation.

408

DIAGNOSTIC RAM  

MEMORY FAILURE:

Control can no longer operate properly due to corrupted data detected in the Operational Data and Status 

Section of RAM memory. Once generated, the Error Mode is not entered nor an error displayed, instead 

previously stored data (<6 hours old) is used to maintain control operation.

410

CONFIG DOWNLOAD:

Configuration file downloaded to the control was not originally uploaded from  

another control with the identical software revision.

Error Codes and Descriptions

REMINDER:

 

Press and hold 

NEXT

 and 

REGEN

 for three seconds to perform a soft reset and clear an error on screen.

Summary of Contents for Impression

Page 1: ...Master Programming Manual for Impression Impression Plus and Impression Twin Models Effective January 2018...

Page 2: ...REGEN TODAY will alternate with the current screen header if a regen is expected tonight Displays current time Unit defaults to this screen after a reset Displays a unit s remaining capacity This scre...

Page 3: ...t backlight operation with or buttons Default setting is ON OFF will turn display backlight off after 5 minutes of keypad inactivity Scrolling contact phone number screen Set phone number by using the...

Page 4: ...or one position to the right Continuing to press the NEXT button will advance to the Contact Name Display Contact name screen Set contact name by using the or buttons Pushing the NEXT button will adva...

Page 5: ...gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen point with or buttons If unit s capacity...

Page 6: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Page 7: ...have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determine a regen and...

Page 8: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Page 9: ...ault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DEL...

Page 10: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Page 11: ...lay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by...

Page 12: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Viewed in 1 0T Mode only 1 indicates most recent tank transfer A i...

Page 13: ...tected or will be the average values measured during generator period of operation AAA Generator current draw in mA VV V Generator voltage in VDC Viewed only if SERVICE OEM is set to OZONE ON Displays...

Page 14: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Page 15: ...15 Notes...

Page 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN IMP MASTER Rev A0118...

Reviews: