12

First Level History Screens 

 

 

 

 

 

 

 

      

Accessed by pressing and holding 

+

 and 

 simultaneously for three seconds. 

Returns to general display after five minutes of inactivity. 

DAYS SINCE REGEN

5

VOLUME SINCE REGEN

980

RESERVE FOR

MON

GAL

GAL

320

GAL

230

USAGE 

WED    R

DAY

15

A

B

GAL

0.00

1  3 DAYS 12:35

1

2

3

4

Displays number of days since last regen.

Displays number of gallons since last regen.

Displays reserve capacity.

Use + or — buttons to scroll through each day of the week to 

view calculated reserve capacity. 

NOTE:

 Reserve capacity takes 21 days to generate. 

Only appears 

on units set to 

1.0T Mode

Displays tank transfer history.

Use + or — buttons to scroll through last 10 tank transfers. 

Viewed in 1.0T Mode only

.

• “1” indicates most recent tank transfer.

• “A” indicates service flow transferring away from tank.

• “B” indicates service flow transferring to tank.

• “3” indicates days ago of transfer (99 day max)

• “0.00” indicates gallons used at time of transfer. 

Displays gallon usage history.

Use + or — buttons to scroll through past 90 days of water usage history.  

1.0T Mode:

 T1 and T2 usage for this day combined in this display

• “R” indicates a regen has occurred that day.

• “S” indicates a step through manual regeneration. 

• “M” indicates a manual regeneration.

• “E” indicates a valve error has occurred.

continue to next page

Summary of Contents for Impression

Page 1: ...Master Programming Manual for Impression Impression Plus and Impression Twin Models Effective January 2018...

Page 2: ...REGEN TODAY will alternate with the current screen header if a regen is expected tonight Displays current time Unit defaults to this screen after a reset Displays a unit s remaining capacity This scre...

Page 3: ...t backlight operation with or buttons Default setting is ON OFF will turn display backlight off after 5 minutes of keypad inactivity Scrolling contact phone number screen Set phone number by using the...

Page 4: ...or one position to the right Continuing to press the NEXT button will advance to the Contact Name Display Contact name screen Set contact name by using the or buttons Pushing the NEXT button will adva...

Page 5: ...gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen point with or buttons If unit s capacity...

Page 6: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Page 7: ...have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determine a regen and...

Page 8: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Page 9: ...ault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DEL...

Page 10: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Page 11: ...lay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by...

Page 12: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Viewed in 1 0T Mode only 1 indicates most recent tank transfer A i...

Page 13: ...tected or will be the average values measured during generator period of operation AAA Generator current draw in mA VV V Generator voltage in VDC Viewed only if SERVICE OEM is set to OZONE ON Displays...

Page 14: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Page 15: ...15 Notes...

Page 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN IMP MASTER Rev A0118...

Reviews: