The  control  valve  with  a  water  meter  can  be  set  for  Demand  Initiated  Regeneration  (DIR)  only,  Time  Clock 
operation  only  or  DIR  and  Time  Clock  whichever  comes  first,  depending  upon  what  settings  are  selected  for  Day 
Override and Gallon Capacity.2 See Table 8. 

 

If a control valve does not contain a meter, the valve can only act as a time clock, and day override should be set to 
any number and gallon capacity should be set to off. 

 

For  DIR  Softeners,  there  are  two  options  for  setting  the  Gallons  Capacity.  The  Gallons  Capacity  is  automatically 
calculated if set to AUTO. Reserve Capacity is automatically estimated based on water usage if AUTO is used. The 
other option is to set the Gallons Capacity to a specific number. If a specific number is set, reserve capacity is zero, 
unless  the  value  is  manually  set  (i.e.  the  manufacturer  intentionally  sets  the  gallon  capacity  number  below  the 
calculated capacity of the system). 

 

The  control  valve  can  also  be  set  to  regenerate  immediately  or  at  the  next  regeneration  time  by  changing  the 
Regeneration Time Option. There are three choices for settings: 
1. “NORMAL” means regeneration will occur at the preset regeneration time. 
2. “on 0” means regeneration will occur when the gallons capacity reaches zero. 
3.  “NORMAL”  and  “on  0”  means  the  regeneration  will  occur  at  the  preset  regeneration  time  unless  the  gallons 
capacity  reaches  zero.  If  the  gallons  capacity  reaches  zero  the  regeneration  will  begin  10  minutes  after  no  water 
usage. 

 

The  user  can  initiate  manual  regeneration.  The  user  has  the  option  to  request  the  manual  regeneration  at  the 
delayed regeneration time or to have the regeneration occur immediately: 
1.  Pressing  and  releasing  the  REGE

N  button.  “Regen  Today”  will  flash  on  the  display  and  the  regeneration  will 

occur  at  the  delayed  regeneration  time.  The  user  can  cancel  the  request  by  pressing  and  releasing  the  REGEN 
button.  This  method  of 

manually  initiating  regeneration  is  not  allowed  when  the  system  is  set  to  “on  0,”  i.e. 

immediately regenerate when the gallon capacity reaches zero. 
2. Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration. The 
user  cannot  cancel  this  request,  except  by  resetting  the  control  by  pressing  NEXT  and  REGEN  buttons 
simultaneously for 3 seconds. 

 

A unique feature of this control valve is the ability to display actual water usage for the last 63 days. The values are 
initially stored 

as “----”. This means the value is unknown. As days pass values are stored as “0” for no flow or the 

actual number of gallons. The counting of the gallons starts at the regeneration time. If no regeneration time can be 
set  (i.e.  when  the  valve  is  set  for  immediate  regeneration)  the  counting  of  gallons  starts  at  12  a.m.  Day  1  is 
yesterday, day 2 the day before yesterday, etc. As new values are added the oldest history disappears. 

 

Another unique feature is that the valve automatically calculates a reserve capacity when set up as a softener with 
“Gallons  Capacity”  set  to  “AUTO”  and  the  “Regeneration  Time  Option”  set  to  “Normal”  or  “Normal  +  on  0”.  The 
actual reserve capacity is compared to the gallons capacity remaining immediately prior to the preset regeneration 
time. A regeneration will occur if the actual reserve capacity is less than the gallons capacity remaining. The actual 
reserve capacity is calculated by using the estimated reserve capacity and adjusting it up or down for actual usage. 

 

The estimated reserve capacity for a given day of the week is the maximum value stored for the last three non-trivial 
water usages (i.e. more than 20 gallons/day) in seven day intervals. 

 

² See Installer Display Settings Step 3I, OEM System Setup Step 7S for explanations of Day Override and Gallon 
Capacity. 
³ Day Override and Gallon Capacity can

not both be set to “oFF” at the same time. 

Summary of Contents for Deluxe Series

Page 1: ...PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN A...

Page 2: ...LATION INSTRUCTIONS This unit has a control valve which enables the setting of not only the length of each regeneration cycle but also the order in which cycles steps of regeneration occur The followi...

Page 3: ...2 CONTROL VALVE SPECIFICATIONS...

Page 4: ...service the valve include one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disa...

Page 5: ...nse cycle or have the regenerant prefill before regeneration If the OEM chooses to have the regenerant prefill before regeneration the prefill starts four hours before the regeneration time set During...

Page 6: ...5 Table 4 Down Flow Softener Program Codes Table 5 Up Flow Softener Program Codes Table 6 Regenerating Filter Program Codes Table 7 Non Regenerating Filter Program Codes...

Page 7: ...on time The user can cancel the request by pressing and releasing the REGEN button This method of manually initiating regeneration is not allowed when the system is set to on 0 i e immediately regener...

Page 8: ...as time of day gallons remaining or days remaining before regeneration current ow rate or total gallons used are shown When stepping through a procedure if no buttons are pressed within ve minutes th...

Page 9: ...d on the printed circuit board Following is an explanation of the options Off Feature not used dPon0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur immediat...

Page 10: ...t Gallons Capacity using or buttons AUTO reserve capacity automatically estimated and gallons capacity automatically calculated from grains capacity and water hardness oFF regeneration based on day ov...

Page 11: ...lons using the or buttons The choices are Relay Actuation Time After the start of a regeneration the amount of time that should pass prior to activating the relay The start of regeneration is de ned a...

Page 12: ...11 SETTING OPTIONS TABLE STEP 1I STEP 2I STEP 3I STEP 4I 4 Reserve capacity estimate is based on history of water usage...

Page 13: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Page 14: ...cord is furnished The tanks should be on a firm level surface The plug in transformer is for dry locations only Electrical Use a 115 120V 60Hz uninterrupted outlet Batteries are not used 1 The distan...

Page 15: ...th the drain connection on the control valve This will provide an adequate anti siphon trap Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its disc...

Page 16: ...ll be called for on that day even if sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons number of days between regeneration 1 to 28 or oFF See Sett...

Page 17: ...lay shows the current treated water ow rate through the system The fourth display shows the total amount of treated water from 1x1000 to 9999x1000 gallons This is resettable by simultaneously pressing...

Page 18: ...t the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the request Note If the regeneration time option is...

Page 19: ...f an extended power outage occurs the time of day will ash on and off which indicates the time of day should be reset The system will remember the rest ERROR MESSAGE If the word ERROR and a number are...

Page 20: ...ily to the drain without the presence of air restore power and momentarily press the REGEN button to advance the control to the BRINE position 5 Fully open the inlet bypass valve handle bypass is now...

Page 21: ...2 sets of dry contacts for user applications The wiring of these contacts is application speci c Relay Speci cations To insure proper t and correct operation the following relay and relay socket manu...

Page 22: ...ck Assembly 1 2 V3004 Drive Cap ASY 1 3 V3372 WS1MR Drive Back Plate 1 4a V3011 WS1 Piston Down ow ASY 1 4b V3011 01 WS1 Piston Up ow ASY 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O...

Page 23: ...22 REPLACEMENT PARTS...

Page 24: ...23 REPLACEMENT PARTS...

Page 25: ...24 REPLACEMENT PARTS...

Page 26: ...25 REPLACEMENT PARTS...

Page 27: ...26 INSTALLATION FITTING ASSEMBLIES...

Page 28: ...27 WS1 IDENTIFICATION FIGURE WS1 WITH 1 050 DISTRIBUTOR TUBE OPENING IDENTIFICATION...

Page 29: ...et time of regeneration d Control set at on 0 d Check with regen time option in programming e Control set at NORMAL on 0 e Check with regen time option in programming 5 ERROR followed by a code number...

Page 30: ...gged a Connect transformer and PC board power b No power at outlet b Restore power c Broken drive gear of drive cap assembly c Replace gear or drive cap assembly d Defective PC board d Replace board 8...

Page 31: ...431 HURONIA RD UNIT 8 BARRIE ONTARIO L4N 9B3 www waterdepotinc com...

Reviews: