CONTROL VALVE FUNCTION AND CYCLES OF OPERATION

This glass filled Noryl¹ (or equivalent) fully automatic control valve is designed as the primary control center to direct 
and regulate all cycles of a water softener or filter. When the WS1MR control valve is manufactured as a softener, 
the control valve can be ordered to perform downflow or upflow regeneration. The WS1.25MR control valve is only 
available in downflow regeneration. When the WS1MR or WS1.25MR control valve is set up as a  filter, the control 
valve can be set to perform downflow regeneration or simply backwash. The control valve can be set to regenerate 
on  demand  (consumption  of  a  predetermined  amount  of  water)  and/or  as  a  time  clock  (passage  of  a  particular 
number  of  days).  The  control  valve  can  be  set  so  that  a  softener  can  meet  the  Water  Quality  Association  (WQA) 
Standard S100 or NSF/ANSI Standard 44 efficiency rating. 

 

 

It is 

not recommended to change control valves from downflow to upflow brining or vice versa in the  field. 

The  valve  bodies  for  downflow  and  upflow  are  unique  to  the  regeneration  type  and  should  not  be 
interchanged.  A  mismatch  of  valve  body  and  regeneration  piston  will  result  in  hard  water  bypass  during 
service. 

 

The  control  valve  is  compatible  with  a  variety  of  regenerants  and  resin  cleaners.  The  control  valve  is  capable  of 
routing the flow of water in the necessary paths to regenerate or backwash  water treatment systems. The injector 
regulates the flow of brine or other regenerants. The control valve regulates the flow rates for backwashing, rinsing, 
and the replenishing of treated water into a regenerant tank, when applicable.  

 

The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts and snap type 
latches  are  used.  Caps  and  nuts  only  need  to  be  firmly  hand  tightened  because  radial  seals  are  used.  Tools 
required to service the valve include one small blade screw driver, one large blade screw driver, pliers and a pair of 
hands.  A  plastic  wrench  is  available  which  eliminates  the  need  for  screwdrivers  and  pliers.  Disassembly  for 
servicing  takes  much  less  time  than  com  parable  products  currently  on  the  market.  Control  valve  installation  is 
made easy because the distributor tube can be cut ½” above to ½” below the top of tank thread. The distributor tube 
is held in place by an o-ring seal and the control valve also has a bayonet lock feature for upper distributor baskets.  
The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve. The 
AC  adapter  power  pack  is  for  dry  location  use  only.  The  control  valve  remembers  all  settings  for  two  hours  if  the 
power  goes  out.  After  two  hours,  the  only  item  that  needs  to  be  reset  is  the  time  of  day;  all  other  values  are 
permanently stored in the non-volatile memory. The control valve does not need batteries.  

 

The control valve‟s unique design and electronics allow the OEM to select:  

1. a pre or pos

t fill option with up or down flow and adjust the length of the cycles; or  

2. 

a pre or post fill option, select a program code that has a preset cycle order/value and adjustable fill cycle.  

 

Tables 1 and 2 show examples when the valve is set up as a softener or a filter. 
 

WS1MR 

Downflow Regenerant 

Refill After Rinse 

 

1

st

 Cycle    Backwash 

2

nd

 Cycle   Regenerate 

3

rd

 Cycle    Second                      

                  Backwash* 
4

th

 Cycle    Rinse 

5

th

 Cycle    Fill/Dissolve 

6

th

 Cycle    Service 

WS1MR 

Downflow Regenerant 

Prefill 

 
1

st

 Cycle    Fill 

2

nd

 Cycle   Service 

3

rd

 Cycle    Backwash 

4

th

 Cycle    Regenerate 

5

th

 Cycle    Second 

                  Backwash* 
6

th

 Cycle    Rinse 

7

th

 Cycle    Service 

WS1MR 

Upflow Regenerant 

Refill After Rinse 

 

1

st

 Cycle    Regenerate 

2

nd

 Cycle   Backwash 

3

rd

 Cycle    Rinse 

4

th

 Cycle    Fill/Dissolve 

5

th

 Cycle    Service 

 

WS1MR 

Upflow Regenerant 

Prefill 

 

1

st

 Cycle    Fill 

2

nd

 Cycle   Service 

3

rd

 Cycle    Regenerate 

4

th

 Cycle    Backwash 

5

th

 Cycle    Rinse 

6

th

 Cycle    Service 

* Second Backwash is optional 

 

 

1

 Noryl is a trademark of General Electric. 

 

 

Summary of Contents for Deluxe Series

Page 1: ...PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN A...

Page 2: ...LATION INSTRUCTIONS This unit has a control valve which enables the setting of not only the length of each regeneration cycle but also the order in which cycles steps of regeneration occur The followi...

Page 3: ...2 CONTROL VALVE SPECIFICATIONS...

Page 4: ...service the valve include one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disa...

Page 5: ...nse cycle or have the regenerant prefill before regeneration If the OEM chooses to have the regenerant prefill before regeneration the prefill starts four hours before the regeneration time set During...

Page 6: ...5 Table 4 Down Flow Softener Program Codes Table 5 Up Flow Softener Program Codes Table 6 Regenerating Filter Program Codes Table 7 Non Regenerating Filter Program Codes...

Page 7: ...on time The user can cancel the request by pressing and releasing the REGEN button This method of manually initiating regeneration is not allowed when the system is set to on 0 i e immediately regener...

Page 8: ...as time of day gallons remaining or days remaining before regeneration current ow rate or total gallons used are shown When stepping through a procedure if no buttons are pressed within ve minutes th...

Page 9: ...d on the printed circuit board Following is an explanation of the options Off Feature not used dPon0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur immediat...

Page 10: ...t Gallons Capacity using or buttons AUTO reserve capacity automatically estimated and gallons capacity automatically calculated from grains capacity and water hardness oFF regeneration based on day ov...

Page 11: ...lons using the or buttons The choices are Relay Actuation Time After the start of a regeneration the amount of time that should pass prior to activating the relay The start of regeneration is de ned a...

Page 12: ...11 SETTING OPTIONS TABLE STEP 1I STEP 2I STEP 3I STEP 4I 4 Reserve capacity estimate is based on history of water usage...

Page 13: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Page 14: ...cord is furnished The tanks should be on a firm level surface The plug in transformer is for dry locations only Electrical Use a 115 120V 60Hz uninterrupted outlet Batteries are not used 1 The distan...

Page 15: ...th the drain connection on the control valve This will provide an adequate anti siphon trap Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its disc...

Page 16: ...ll be called for on that day even if sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons number of days between regeneration 1 to 28 or oFF See Sett...

Page 17: ...lay shows the current treated water ow rate through the system The fourth display shows the total amount of treated water from 1x1000 to 9999x1000 gallons This is resettable by simultaneously pressing...

Page 18: ...t the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the request Note If the regeneration time option is...

Page 19: ...f an extended power outage occurs the time of day will ash on and off which indicates the time of day should be reset The system will remember the rest ERROR MESSAGE If the word ERROR and a number are...

Page 20: ...ily to the drain without the presence of air restore power and momentarily press the REGEN button to advance the control to the BRINE position 5 Fully open the inlet bypass valve handle bypass is now...

Page 21: ...2 sets of dry contacts for user applications The wiring of these contacts is application speci c Relay Speci cations To insure proper t and correct operation the following relay and relay socket manu...

Page 22: ...ck Assembly 1 2 V3004 Drive Cap ASY 1 3 V3372 WS1MR Drive Back Plate 1 4a V3011 WS1 Piston Down ow ASY 1 4b V3011 01 WS1 Piston Up ow ASY 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O...

Page 23: ...22 REPLACEMENT PARTS...

Page 24: ...23 REPLACEMENT PARTS...

Page 25: ...24 REPLACEMENT PARTS...

Page 26: ...25 REPLACEMENT PARTS...

Page 27: ...26 INSTALLATION FITTING ASSEMBLIES...

Page 28: ...27 WS1 IDENTIFICATION FIGURE WS1 WITH 1 050 DISTRIBUTOR TUBE OPENING IDENTIFICATION...

Page 29: ...et time of regeneration d Control set at on 0 d Check with regen time option in programming e Control set at NORMAL on 0 e Check with regen time option in programming 5 ERROR followed by a code number...

Page 30: ...gged a Connect transformer and PC board power b No power at outlet b Restore power c Broken drive gear of drive cap assembly c Replace gear or drive cap assembly d Defective PC board d Replace board 8...

Page 31: ...431 HURONIA RD UNIT 8 BARRIE ONTARIO L4N 9B3 www waterdepotinc com...

Reviews: