REGENERATION MODE

 

Typically  a  system  is  set  to  regenerate  at  a  time  of  low  water  usage.  An 
example of a time with low water usage is when a household is asleep. If 
there  is  a  demand  for  water  when  the  system  is  regenerating,  untreated 
water will be used.  
 
When  the  system  begins  to  regenerate,  the  display  will  change  to  include  information  about  the  step  of  the 
regeneration  process  and  the  time  remaining  for  that  step  to  be  completed.  The  system  runs  through  the  steps 
automatically and will reset itself to provide treated water when the regeneration has been completed.  
 

MANUAL REGENERATION

 

Sometimes  there  is  a  need  to  regenerate  the  system 
sooner than when the system calls for it, usually referred 
to  as  manual  regeneration.  There  may  be  a  period  of 
heavy water usage because of guests or a heavy laundry 
day.  

 

To  initiate  a  manual  regeneration  at  the  preset  delayed 
regeneration  time,  when  the  regeneration  time  option  is 
set to “NORMAL” or “ on 0”, press and release “REGEN”.  
The  words  “REGEN  TODAY”  will  flash  on  the  display  to  indicate  that  the  system  will  regenerate  at  the  preset 
delayed  regeneration  time.  If  you  pressed  the  “REGEN”  button  in  error,  pressing  the  button  again  will  cancel  the 
request. Note: If the regeneration time option is set to “on 0” there is no set delayed regeneration time so “REGEN 
TODAY” will not activate if “REGEN” button is pressed.  
 
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system 
will begin to regenerate immediately. The request cannot be cancelled.  
 
Note: For soft

eners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating. 

  

 

SET TIME OF DAY

  

The user can also set the time of day. Time of day should only need to be set 
after extended power outages or when daylight saving time begins or ends. If 
an extended power outage occurs, the time of day will flash on and off which 
indicates the time of day should be reset.  

STEP 1U

 

– Press CLOCK.  

STEP 2U 

 

STEP  2U

  - 

Current  Time  (hour):  Set  the  hour  of  the  day  using  ▲  and  ▼ 

buttons. AM/PM toggles after 12. Press NEXT to go to step 3U.  

 
 
 
 
 
 
 
 
STEP 3U

 - 

Current Time (minutes): Set the minutes of the day using ▲ and ▼ 

buttons.  Press  NEXT  to  exit  Set  Time  of  Day.  Press  REGEN  to  return  to 
previous step.  

STEP 3U 

 

STEP 1D 

 

STEP 2D 

 

STEP 3D 

 

STEP 4D 

 

STEP 5D

 

Summary of Contents for Deluxe Series

Page 1: ...PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN A...

Page 2: ...LATION INSTRUCTIONS This unit has a control valve which enables the setting of not only the length of each regeneration cycle but also the order in which cycles steps of regeneration occur The followi...

Page 3: ...2 CONTROL VALVE SPECIFICATIONS...

Page 4: ...service the valve include one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disa...

Page 5: ...nse cycle or have the regenerant prefill before regeneration If the OEM chooses to have the regenerant prefill before regeneration the prefill starts four hours before the regeneration time set During...

Page 6: ...5 Table 4 Down Flow Softener Program Codes Table 5 Up Flow Softener Program Codes Table 6 Regenerating Filter Program Codes Table 7 Non Regenerating Filter Program Codes...

Page 7: ...on time The user can cancel the request by pressing and releasing the REGEN button This method of manually initiating regeneration is not allowed when the system is set to on 0 i e immediately regener...

Page 8: ...as time of day gallons remaining or days remaining before regeneration current ow rate or total gallons used are shown When stepping through a procedure if no buttons are pressed within ve minutes th...

Page 9: ...d on the printed circuit board Following is an explanation of the options Off Feature not used dPon0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur immediat...

Page 10: ...t Gallons Capacity using or buttons AUTO reserve capacity automatically estimated and gallons capacity automatically calculated from grains capacity and water hardness oFF regeneration based on day ov...

Page 11: ...lons using the or buttons The choices are Relay Actuation Time After the start of a regeneration the amount of time that should pass prior to activating the relay The start of regeneration is de ned a...

Page 12: ...11 SETTING OPTIONS TABLE STEP 1I STEP 2I STEP 3I STEP 4I 4 Reserve capacity estimate is based on history of water usage...

Page 13: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Page 14: ...cord is furnished The tanks should be on a firm level surface The plug in transformer is for dry locations only Electrical Use a 115 120V 60Hz uninterrupted outlet Batteries are not used 1 The distan...

Page 15: ...th the drain connection on the control valve This will provide an adequate anti siphon trap Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its disc...

Page 16: ...ll be called for on that day even if sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons number of days between regeneration 1 to 28 or oFF See Sett...

Page 17: ...lay shows the current treated water ow rate through the system The fourth display shows the total amount of treated water from 1x1000 to 9999x1000 gallons This is resettable by simultaneously pressing...

Page 18: ...t the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the request Note If the regeneration time option is...

Page 19: ...f an extended power outage occurs the time of day will ash on and off which indicates the time of day should be reset The system will remember the rest ERROR MESSAGE If the word ERROR and a number are...

Page 20: ...ily to the drain without the presence of air restore power and momentarily press the REGEN button to advance the control to the BRINE position 5 Fully open the inlet bypass valve handle bypass is now...

Page 21: ...2 sets of dry contacts for user applications The wiring of these contacts is application speci c Relay Speci cations To insure proper t and correct operation the following relay and relay socket manu...

Page 22: ...ck Assembly 1 2 V3004 Drive Cap ASY 1 3 V3372 WS1MR Drive Back Plate 1 4a V3011 WS1 Piston Down ow ASY 1 4b V3011 01 WS1 Piston Up ow ASY 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O...

Page 23: ...22 REPLACEMENT PARTS...

Page 24: ...23 REPLACEMENT PARTS...

Page 25: ...24 REPLACEMENT PARTS...

Page 26: ...25 REPLACEMENT PARTS...

Page 27: ...26 INSTALLATION FITTING ASSEMBLIES...

Page 28: ...27 WS1 IDENTIFICATION FIGURE WS1 WITH 1 050 DISTRIBUTOR TUBE OPENING IDENTIFICATION...

Page 29: ...et time of regeneration d Control set at on 0 d Check with regen time option in programming e Control set at NORMAL on 0 e Check with regen time option in programming 5 ERROR followed by a code number...

Page 30: ...gged a Connect transformer and PC board power b No power at outlet b Restore power c Broken drive gear of drive cap assembly c Replace gear or drive cap assembly d Defective PC board d Replace board 8...

Page 31: ...431 HURONIA RD UNIT 8 BARRIE ONTARIO L4N 9B3 www waterdepotinc com...

Reviews: