23833A472
7
Cement as many couplings and
sections of rigid PVC pipe on both
the pressure and delivery sides as it
takes to equal the depth of your well
minus four feet, then fi rmly clamp
the assembly with a pipe clamp to
prevent the assembly from sliding
down into the well. Be sure to keep
track of which pipe is the pressure
pipe and which is the delivery pipe.
STEP
5
STEP
6
Cut 1" pipe 2" shorter than the
1-1/4" pipe. Smooth rough
edges. Cement 1" and 1-1/4"
PVC elbows to pipes protruding from
the well seal.
STEP
7
Cement as many
sections and
couplings of
rigid 1" and
1-1/4" PVC as needed to connect the 1" female PVC adapter and
the 1-1/4" male PVC adapter to the 1" and 1-1/4" PVC elbows.
Open pressure regulator kit
RPR. With pipe wrench, thread
the pressure regulator into 1"
discharge at top of pump. Thread
pressure gauge RG-2 into side of
pump case.
Thread plug into opening to right
of pressure regulator outlet.
STEP
8
STEP
10
STEP
11
STEP
16
Complete all electrical connections as specifi ed on
pages 2 and 3 in the preinstallation instructions.
STEP
12
Thread 3/4" male PVC
adapter into pressure
regulator outlet.
STEP
13
TO PRIME: Remove
pressure regulator,
put a garden hose
into the top of the
pump discharge and
fi ll and pump with
water until water overfl ows from top of pump. This may
take several minutes. Put regulator back on pump.
12" OF
PVC PIPE
PROTRUD-
ING FROM
WELL
SEAL
WELL SEAL
1-1/4" PVC
ELBOW
1" PVC
ELBOW
1" PIPE 2"
SHORTER
THAN 1-1/4"
PIPE
1-1/4" MALE
PVC ADAPTER
1" x 4"
NIPPLE
1" FEMALE
PVC
ADAPTER
Thread a 1-1/4" male PVC adapter
into top hole in front of pump.
Thread 1" x 4" nipple into bottom
hole in front of pump. Thread the
1" female PVC adapter onto the 1"
x 4" nipple.
STEP
9
FEMALE ADAPTER
1" PVC PIPE
1-1/4" PVC PIPE
PRESSURE
REGULATOR
PLUG
PRESSURE
REGULATOR
OUTLET
PRIMING DEEP WELL JET PUMPS
3/4" MALE
PVC ADAPTER
Process C, continued.
Remove pipe clamp and slide well
seal RWS4-1012 over PVC pipes
and onto well casing. DO NOT let
assembly slide down into well.
Position assembly so that twelve
inches of PVC pipes protrude
from well seal. Using crescent
wrench, turn bolts on well seal
counterclockwise until rubber
gaskets are tight against the well
casing and the PVC pipes.
Thread tank tee
RTT1-LF into diaphragm
pressure tank. Plug two
outlets on tank tee with
two 1/4" plugs.
STEP
14
Thread boiler drain into
front of tank tee. Thread
3/4" male PVC adapter
into inlet side of tank
tee. Connect to household
plumbing.
STEP
15
1/4" PLUGS
TANK TEE
1/2" BOILER
DRAIN
3/4" MALE
PVC
ADAPTER