23833A472
2
LINE
LINE
MOTOR
MOTOR
INCOMING POWER
GROUND
CONNECTIONS
MOTOR WIRES
IMPORTANT: SELECT CORRECT VOLTAGE
Disconnect pump from power source before changing the pump
voltage. To change the voltage, the selector switch is located
underneath the plastic cover on top of the motor. To access
the switch, remove the eight screws holding the plastic cover.
To change the voltage setting, slide the switch as shown until
desired voltage is visible on the switch. The voltage number that
appears is the voltage setting for the pump. Be sure the switch
is completely engaged. Replace the capacitor cover and secure
the cover with the eight screws.
Wire Selection Guide
#14
#12
#10
#8
118
189
296
464
475
756
1184
1857
100
160
250
385
400
630
1000
1545
84
135
211
331
339
540
845
1327
NAME-
PLATE
AMPS
115
230
115
230
115
230
PUMP
MODEL
HORSE-
POWER
VOLTAGE
8.6
4.3
11.2
5.6
12.6
6.3
MAX. WIRE LENGTH IN FEET
USING AWG SIZE
RTS5
or
RC5
RTS10
or
RC10
1/2
3/4
1
RTS7
20
30
STANDARD LINE
PLUG FUSE*
LOW PEAK - CART. TYPE
FUSETRON - CART. TYPE
FUSTAT - PLUG TYPE*
CIRCUIT BREAKER
HORSE-
POWER
115V
230V
115V
230V
115V
230V
1/2
3/4 & 1
20
30
10
15
12
20
6-1/4
10
15
15
0
0
5
5
10
10
15
15
20
20
25
25
Pumping Depth in Feet
Gallons per Min
ute at 30-50 PSI Pressure
RTS5
RTS7
RTS10
Shallow Well Pump Capacities
For RTS5(1/2HP), RTS7(3/4HP), and RTS10 (1 HP)
Pumping Depth in Feet
Gallons per Min
ute at 30-50 PSI Pressure
Deep Well Pump Capacities
For RC5(1/2HP) and RC10 (1 HP)
20
30
40
50
60
70
80
90
100
14
12
10
8
6
4
2
0
RC5
RC10
FUSE AND CIRCUIT BREAKER SIZE GUIDE
*For circuits not over 150 volts to ground.
WIRING YOUR PUMP
Disconnect pump from power before servicing or handling pump.
Remove the cover from the pressure switch. Connect the bare
copper ground to the ground screw in the pressure switch.
Connect the power supply to the terminals marked “Line" in the
diagram below.
115
15
230
230
115
15
230
230
VOLTAGE SELECTION DIRECTIONS
Warning!
Disconnect pump from your
source before servicing or
handling pump.
Be sure that incoming power
supply is same as voltage
selector switch setting.
To change voltage settings
slide switch as shown
until desired voltage is
visible on switch.
Be sure switch is completely
engaged.
Replace capacitor housing cover
and secure cover with screws.
Do not overtighten screws.
22700A375
PIPING
Plastic PVC pipe is shown in the illustrations, but galvanized
steel pipe may be used if desired. All piping must be clean and
free of all foreign matter to prevent clogging. ALL JOINTS AND
CONNECTIONS IN THE WELL ASSEMBLY MUST BE AIRTIGHT. Even
a pinhole leak will prevent the proper operation of the pump
(this is the most common problem). Use thread compound on all
threaded joints unless specifi ed otherwise.
Process B. Correctly Select Your Pump