![Water Ace 23210D500 Installation Manual Download Page 8](http://html.mh-extra.com/html/water-ace/23210d500/23210d500_installation-manual_874418008.webp)
Bag #23834A004
8
23833A09
Installing a submersible well pump, continued.
COMPLETE
WELL SEAL
INSTALLATION
TO PRESSURE
SWITCH (2-WIRE)
TO CONTROL BOX
(3-WIRE)
OPTIONAL
GATE VALVE
Process B: Steps 1 through 5,
At The Well,
Continued.
STEP
5
B
A typical
well seal
submersible well pump installation
LOWERING THE PUMP
BOTTOM
OF WELL
10 FT. (3 METERS)
MINIMUM
DRAWDOWN
WATER LEVEL
TAPE CABLE
EVERY 10 FT.
(3 METERS)
5 FT. (1-1/2
METERS)
MINIMUM
CHECK VALVE
EVERY 200 FT.
(60 METERS)
SAFETY
CABLE
Process C: Step 1 (only)
Lowering The Pump
With someone’s help, carefully lower pump
assembly into well. Slide pitless pipe junction into
pitless slot. Firmly grasp assembly and safety rope
tied to well cap to prevent assembly from falling
into the well.
After Process C: Step 1
Lowering The Pump
have
been completed, please proceed to Process D:
Steps 1 through 4,
At The House.
STEP
1
Lowering the pump
A
A typical
pitless adapter
submersible well pump installation
CONSUMER HOT-LINE:
1-800-942-3343
(USA only)
Monday–Friday 7 AM to 5 PM EST
www.waterace.com