Bag #23834A004

23833A09

.  Single phase motors are either two wire units (two black 

power wires and a green ground), or three wire units (three 

power leads red, black, and yellow and a green ground). 

The three wire units require a control box. Make sure the 

control  box  matches  the  motor  in  voltage,  horsepower, 

and phase.

2. Single phase motors are equipped with automatic resetting 

thermal  protectors.  The  motor  may  restart  unexpectedly 

causing  the  leads  to  energize  or  pump  to  turn.  Three 

phase motors should be protected by proper thermal and 

amperage protection. (Check local codes.)

3. Check for nicks in the wire and pump insulation by using 

an  ohmmeter  and  checking  resistance  to  ground  before 

installing the pump and after installing the pump. If in 

doubt  on  the  proper  procedure,  check  with  a  qualified 

electrician.

4. The  three  phase  units  must  be  wired  by  a  qualified 

electrician, using an approved starter box and switching 

device.

5.  Do not use this pump in or near a swimming pool, pond, 

lake or river.

6. Do not pump gasoline, chemicals, corrosives or flammable 

liquids; they could ignite, explode, or damage the pump, 

causing injury and voiding the warranty.

.  Before  installing  or  servicing  your  pump,  BE 

CERTAIN THE PUMP POWER SOURCE IS TURNED OFF 

AND DISCONNECTED.

2.  All  installation  and  electrical  wiring  must 

adhere to state and local codes. Check with appropriate 

community agencies, or contact your local electrical and 

pump professionals for help.

  3.  

CALL AN ELECTRICIAN WHEN IN DOUBT

. Pump must be 

connected to a separate electrical circuit directly from the 

entrance box. There must be an appropriately sized fuse 

or circuit breaker in this line. Tying into existing circuits 

may cause circuit overloading, blown fuses, tripped circuit 

breakers, or a burned-up motor.

  4.  Do not connect pump to a power supply until the pump is 

grounded. For maximum safety, a ground fault interrupter 

should be used. CAUTION: FAILURE TO GROUND THIS UNIT 

PROPERLY MAY RESULT IN SEVERE ELECTRICAL SHOCK.

5.

 

WARNING: Reduced risk of electric shock during 

operation  of  this  pump  requires  the  provision 

of  acceptable  grounding:  a)  If  the  means  of 

connection  to  the  supply-connection  box  is 

other  than  grounded  metal  conduit,  ground 

the  pump  back  to  the  service  by  connecting  a 

copper conductor, at least the size of the circuit 

conductors supplying the pump, to the grounding screw 

provided within the wiring compartment. b) This pump 

is provided with a means for grounding. To reduce the 

risk of electric shock from contact with adjacent metal 

parts, bond supply box to the pump-motor-grounding 

means  and  to  all  metal  parts  accessible  at  the  well 

head,  including  metal  discharge  pipes,  metal  well 

casing, and the like, by means of the following...

 

 

 

b1.  An  equipment-grounding  conductor  at  least  the 

size  of  the  well  cable  conductors,  or  the  equivalent, 

that runs down the well with the well cable and, b2. 

A clamp, a weld, or both if necessary, secured to the 

equipment-grounding  lead,  the  equipment-grounding 

terminal,  or  the  grounding  conductor  on  the  pump 

housing.  The  equipment-grounding  lead,  if  one  is 

provided, is the conductor that has an outer surface of 

insulation that is green with or without one or more 

yellow stripes.

  6.  The voltage and phase of the power supply must match 

the voltage and phase of the pump.

  7.  Do not use an extension cord; splices must be made with 

an approved splice kit and should be checked for integrity 

before submerging in water; above ground joints must be 

made in an approved junction box.

  8.  Do not work on this pump or switch while the power is 

on.

  9.  Never operate a pump with a frayed or brittle power cord, 

and always protect it from sharp objects, hot surfaces, oil 

and chemicals. Avoid kinking the cord.

0.  Never service a motor or power cord with wet hands or 

while standing in or near water or damp ground.

Electrical Safety Instructions

 

WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS AND COMPLY WITH ALL 
CODES MAY CAUSE SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

Mechanical Safety Instructions 

7.  Do  not  run  this  pump  with  the  discharge 

completely  closed.  This  will  create  superheated 

water, which could damage the  seal and shorten 

the life of the motor. This superheated water could 

also  cause  severe  burns.  Always  use  a  pressure 

relief  valve,  set  below  the  rating  of  the  tank  or 

system.

8. Pump is capable of building pressures in excess 

of 00 PSI. Always use a pressure relief valve.

9.  The  well,  cistern,  or  pit  must  be  sealed  to 

prevent  a  child,  animal  or  foreign  object  from 

falling in.

20. While the well seal or cap is removed for repairs, cover the 

well to prevent foreign matter from entering, contaminating 

the well, and possibly damaging the pump.

2.  Test  well  water  for  potability;  chlorinating  the  well  or 

purifying is recommended every time the well is opened. 

Check  with  local  health  departments  for  testing  and 

sanitizing procedures.

CAUTION!

22. The following may cause severe damage to the pump and 

void  warranty.  It  could  also  result  in  personal  injury:

Running the pump dry, failure to protect the pump from 

below freezing temperatures, running the pump with the 

discharge  completely  closed,  or  pumping  chemicals  or 

corrosive liquids.

23. Never work on the pump or system without relieving the 

internal pressure.

24. Do not pump water above 20° Fahrenheit.

25. Never exceed the pressure rating of any system component.

Summary of Contents for 23210D500

Page 1: ...Y CAUSE SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE BEFORE YOU BEGIN YOU SHOULD KNOW THE DEPTH OF YOUR WELL WATER ACE SUGGESTS THE FOLLOWING FOUR EASY STEPS IN DETERMINING YOUR WELL DEPTH 2 WIRE MODELS R200A PART NO 232 0D500 2 HP 0 GPM 5 V R201A PART NO 232 4D500 2 HP 0 GPM R202A PART NO 232 8D500 3 4 HP 0 GPM R203A PART NO 23222D500 HP 0 GPM R214A PART NO 23225D500 2 HP 6 GPM R2254A PART NO 243...

Page 2: ...grounding means and to all metal parts accessible at the well head including metal discharge pipes metal well casing and the like by means of the following b1 An equipment grounding conductor at least the size of the well cable conductors or the equivalent that runs down the well with the well cable and b2 A clamp a weld or both if necessary secured to the equipment grounding lead the equipment gr...

Page 3: ...r burnout Refer to the performance table on page 4 to determine which pump best fits your needs The performance table illustrates each model s pumping capacity in gallons per minute GPM as compared to various depths measured in feet What materials will I need for installation What size wire will I need Electrical cable see size chart RHS 3 insulation splice kit ground wire flexible plastic pipe we...

Page 4: ...5 8 5 R301A R3067A 6 3 4 7 7 7 6 7 4 7 0 6 6 6 2 5 8 5 0 R3207A 18 3 4 15 3 R203A 10 1 14 4 13 4 12 1 10 7 9 3 7 4 R302A R30610A 6 1 8 0 7 9 7 7 7 5 7 2 6 9 6 5 5 7 5 0 4 2 R3183A 18 1 22 5 21 2 20 0 R31015A 10 1 1 2 14 9 14 3 13 6 12 0 10 0 7 6 R214A 6 1 1 2 11 2 10 8 10 2 9 2 8 0 6 6 5 0 R314A R3184A 18 1 1 2 23 2 22 5 21 4 20 0 17 9 14 5 R2254A 25 1 1 2 25 4 21 0 15 0 R3254A R2354A 35 1 1 2 R33...

Page 5: ...nk tube over crimped joint Apply heat with torch or butane lighter Heat one tube at a time see figure C Do not let tubes touch each other while heating When liquid oozes from end of tube seal is complete See Cable Splice Check on page 6 to check for leaks STEP 1 STEP 2 How do I install a submersible well pump Subtract twelve feet from the depth of well see page 1 Knowing the Depth of Your Well Thi...

Page 6: ...e where it is damaged or has a leaky splice It must be repaired with a cable splice kit Installing a submersible well pump continued Process A Steps 1 through 5 At The Pump Cable Continued Splice Check STEP 5 You may write the installation date service date and other important notes regarding your well pump for your records here __________________________________________________________ __________...

Page 7: ...sing Place other washer fitting and lock nut on slot threads protruding from casing Tighten securely The slot has interior threads as well Thread a 1 male PVC adapter into the slot see figure L With someone s help carefully lower pump assembly into well Slide pitless pipe junction into pitless slot see figure M Firmly grasp assembly and safety rope tied to well cap to prevent assembly from falling...

Page 8: ...ETERS MINIMUM CHECK VALVE EVERY 200 FT 60 METERS SAFETY CABLE Process C Step 1 only Lowering The Pump With someone s help carefully lower pump assembly into well Slide pitless pipe junction into pitless slot Firmly grasp assembly and safety rope tied to well cap to prevent assembly from falling into the well After Process C Step 1 Lowering The Pump have been completed please proceed to Process D S...

Page 9: ...d pressure gauge RG 2 into right 1 4 hole of tank cross Cut and cement as many sections and couplings of PVC pipe needed to connect the 1 male PVC adapter on the gate valve to 1 male PVC adapter on the pitless slot assembly Complete installation should look like the drawing on the following page T 3 4 BOILER DAIN ANK CROSS RTC 290 1 3 4 PRESSURE RELIEF VALVE RRV 75 1 4 NIPP 1 MALE PVC ADAPTER PRES...

Page 10: ...e of the ground screws at base of pressure switch Run wires from control box terminals labelled L1 and L2 to two inside pressure switch terminals numbers 2 3 Run wires from two outside pressure switch terminals lines 1 4 to fuse box power supply Run wire from ground screw to fuse box ground bar For Minimum Entrance Box Service Rating see chart below FROM CONTROL BOX TO FUSE BOX POWER SUPPLY 3 2 1 ...

Page 11: ...15 VOLT HOOKUP A SINGLE POLE BREAKER IS USED THIS BREAKER CONTACTS ONLY ONE BUSS BAR THE GROUND IS HOOKED TO THE NEUTRAL BAR THE WHITE WIRE IS ALSO HOOKED UP TO THE NEUTRAL BAR GREEN GROUND BLACK POWER WHITE NEUTRAL DANGEROUS 230 VOLT HOOKUP TWO SINGLE POLE BREAKERS WILL WORK HOWEVER IF ONE TRIPS THE UNIT WON T WORK BUT THE MOTOR COULD STILL BE LIVE AND SOMEONE COULD GET SHOCKED GREEN GROUND BLACK...

Page 12: ... INSTRUCTIONS IN THE INSTALLATION MANUAL WHEN IN DOUBT CONSULT A PROFESSIONAL Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In the absence of suitable proof of this purchase date the e...

Page 13: ...onnue Déterminer la profondeur d un puits ÉTAPE 1 Attachez soigneusement un petit poids relativement lourd à l extrémité d une corde assurez vous d avoir une corde assez longue car certains puits sont très profonds Descendez le poids dans le puits jusqu à ce qu il atteigne le fond ÉTAPE 2 Assurez vous que la corde est tendue et faites une marque sur la corde au niveau du sol Sortez le poids du pui...

Page 14: ...t le tubage métallique du puits et autre grâce au matériel suivant b1 Un conducteur de mise à la terre d équipement dont la grosseur est au moins équivalente aux conducteurs du câble du puits ou l équivalent qui descend dans le puits avec le câble du puits et b2 Une bride une soudure ou les deux si nécessaire fixée au conducteur de mise à la terre de l équipement à la borne de mise à la terre de l...

Page 15: ...vient le mieux à vos besoins veuillez consulter le tableau de performances de la page 4 Ce tableau de performances indique les capacités des divers modèles de pompes en gallons par minute GPM avec diverses profondeurs exprimées en pieds 1 pied 0 3048 m Quels matériaux sont nécessaires pour l installation Quelle doit être la grosseur des câbles électriques Câble électrique voir tableau de grosseurs...

Page 16: ... 7 4 7 0 6 6 6 2 5 8 5 0 R3207A 18 3 4 15 3 R203A 10 1 14 4 13 4 12 1 10 7 9 3 7 4 R302A R30610A 6 1 8 0 7 9 7 7 7 5 7 2 6 9 6 5 5 7 5 0 4 2 R3183A 18 1 22 5 21 2 20 0 R31015A 10 1 1 2 14 9 14 3 13 6 12 0 10 0 7 6 R214A 6 1 1 2 11 2 10 8 10 2 9 2 8 0 6 6 5 0 R314A R3184A 18 1 1 2 23 2 22 5 21 4 20 0 17 9 14 5 R2254A 25 1 1 2 25 4 21 0 15 0 R3254A R2354A 35 1 1 2 R3354A R32551A 25 2 26 9 22 8 18 0 ...

Page 17: ...nche est terminé Reportez vous en page 6 sous Vérification des épissures pour vous assurer qu il n y a pas de fuite ÉTAPE 1 ÉTAPE 2 Quelle est la procédure à suivre pour installer une pompe de puits submersible Soustrayez douze pieds de la profondeur du puits voir en page 1 sous Déterminer la profondeur d un puits La mesure obtenue correspond à la longueur de tuyau en plastique nécessaire pour le ...

Page 18: ...pond à l endroit où le câble est endommagé ou au site de l épissure défectueuse Effectuez la réparation avec un kit d épissage Installation d une pompe de puits submersible suite Procédure A Étapes 1 à 5 sur la pompe suite vérification des épissures ÉTAPE 5 Vous pouvez inscrire ici la date d installation une date de réparation ou d autres notes importantes concernant la pompe de puits ____________...

Page 19: ...teur est également dotée d un filetage intérieur Vissez un adaptateur en PVC mâle de 1 po dans le connecteur voir la figure L Avec l aide de quelqu un descendez soigneusement la pompe dans le puits Emboîtez la jonction de tuyau et le coulisseau de raccordement voir la figure M Saisissez fermement l assemblage et la corde de sécurité attachée au couvercle du puits pour éviter que l assemblage tombe...

Page 20: ...on de pompe submersible DESCENTE DE LA POMPE FOND DU PUITS MINIMUM 10 PI 3 M NIVEAU DE CHUTE RETENIR LE CÂBLE AVEC DU RUBAN ADHÉSIF TOUS LES 10 PI 3 M MINIMUM 5 PI 1 5 M CLAPET ANTI RETOUR TOUS LES 200 PI 60 M CÂBLE DE SÉCURITÉ Procédure C Étape 1 seulement Descente de la pompe Descente de la pompe A Coulisseau de raccordement typique installation de pompe submersible ASSISTANCE TÉLÉPHONIQUE 1 800...

Page 21: ...ressembler au schéma de la page suivante CROIX DE RÉSERVOIR RTC 290 1 ÉCOULEMENT DE CHAUDIÈRE DE 3 4 PODAIN SOUPAPE DE DÉCHARGE RRV 75 DE 3 4 PO ADAPTATEUR EN PVC MÂLE DE 1 PO MAMELON 1 4 PO X 3 PO PRESSOSTAT RPS MAMELON 1 4 PO X 3 PO MANOSTAT RG 2 Pompe Pompe Kit d épissage thermorétractable Kit d épissage thermorétractable Tuyau en plastique de puits profond Tuyau en plastique de puits profond N...

Page 22: ...res du pressostat n 2 et 3 Faites passer des fils depuis les deux bornes à l extérieur du pressostat n 1 et 4 jusqu à la boîte de fusibles ou d entrée électrique Faites passer un fil depuis la vis de terre jusqu à la barre de terre de la boîte de fusibles Pour connaître les capacités minimales s appliquant à la boîte d entrée électrique voir le tableau ci dessous CONNEXIONS BIFILAIRES VERS BOÎTE D...

Page 23: ...ONCTIONNERA MÊME SI L UN DES DEUX EST DÉCLENCHÉ DANS CE CAS L APPAREIL NE FONCTIONNE PAS MAIS LE MOTEUR PEUT QUAND MÊME ÊTRE SOUS TENSION ET ÉLECTROCUTER QUELQU UN DANGER LE RACCORDEMENT SOUS 230V DES DEUX DISJONCTEURS UNIPOLAIRES NE FONCTIONNERA PAS EN GÉNÉRAL L INSTALLATEUR MESURE LA TENSION ENTRE CHAQUE FIL ET LA TERRE ET OBTIENT UNE MESURE DE 115V S IL MESURE DE LIGNE À LIGNE IL OBTIENT UNE ME...

Page 24: ...cts ou consécutifs il est possible que l exclusion ou restriction ci dessus ne s applique pas à vous Cette garantie vous accorde des droits juridiques précis mais il est possible que vous ayez également d autres droits selon votre lieu de résidence En l absence d une preuve acceptable de la date d achat de ce produit la période d application de la garantie sera basée sur la date de fabrication Env...

Page 25: ...l extremo de una cuerda asegúrese de que haya cuerda suficiente algunos pozos son muy profundos Baje el peso por el pozo hasta llegar al fondo PASO 2 Tense la cuerda y márquela a nivel del suelo Saque el peso del pozo y mida desde el fondo del peso hasta la marca de nivel del suelo Ésta será la profundidad de su pozo PASO 3 Reste tres metros a esta profundidad El número calculado no deberá sobrepa...

Page 26: ... metal accesibles en el cabezal del pozo incluidas las tuberías metálicas de descarga el revestimiento metálico del pozo y a otros elementos similares mediante lo siguiente b1 Un conductor de conexión a tierra del equipo que sea al menos del tamaño de los conductores del cable del pozo o un elemento equivalente que se introduzca en el pozo junto con el cable del pozo y b2 una abrazadera una soldad...

Page 27: ...recuencia lo que podrá llevar a quemar el motor Consulte la tabla de rendimientos de la página 4 para determinar la bomba que mejor se ajuste a sus necesidades La tabla de rendimiento ilustra la capacidad de bombeo de cada modelo en galones por minuto GPM en comparación con las varias profundidades medidas en pies Qué materiales necesitaré para la instalación Qué tamaño de conductor necesitaré Cab...

Page 28: ... 7 7 7 6 7 4 7 0 6 6 6 2 5 8 5 0 R3207A 18 3 4 15 3 R203A 10 1 14 4 13 4 12 1 10 7 9 3 7 4 R302A R30610A 6 1 8 0 7 9 7 7 7 5 7 2 6 9 6 5 5 7 5 0 4 2 R3183A 18 1 22 5 21 2 20 0 R31015A 10 1 1 2 14 9 14 3 13 6 12 0 10 0 7 6 R214A 6 1 1 2 11 2 10 8 10 2 9 2 8 0 6 6 5 0 R314A R3184A 18 1 1 2 23 2 22 5 21 4 20 0 17 9 14 5 R2254A 25 1 1 2 25 4 21 0 15 0 R3254A R2354A 35 1 1 2 R3354A R32551A 25 2 26 9 22...

Page 29: ...ello es tará completo Véase la sección de Revisión de empalmes del cable en la página 6 para verificar si hay fugas PASO 1 PASO 2 Cómo instalo una bomba sumergible para pozos Reste doce pies a la profundidad del pozo ver página 1 Cómo conocer la profundidad de su pozo Ésta será la longitud total de la tuber ía de polietileno necesaria para sujetarla con una abrazadera al adaptador macho dentado de...

Page 30: ...able esté dañado o tenga un empalme con pérdida Deberá repararse con un juego de empalmes para cables Instalación de una bomba sumergible para pozo continuación Proceso A pasos 1 al 5 Con el cable de la bomba continuación Prueba para empalmes PASO 5 Podrá anotar la fecha de instalación la fecha de servicio y otros datos importantes con relación a su bomba para pozos aquí para sus propios registros...

Page 31: ...evestimiento Apriete bien La ranura tiene también roscas interiores Enrosque un adaptador macho de cloruro de polivinilo de 1 pulgada en la ranura véase la ilustración L Con la ayuda de alguna persona baje con cuidado el ensamblaje de la bomba en el pozo Introduzca la conexión de tubos horizontal en la ranura horizontal véase la ilustración M Agarre firmemente el ensamblaje y la cuerda de segurida...

Page 32: ...ica de una bomba sumergible para pozos con sello DESCENSO DE LA BOMBA FONDO DEL POZO MÍNIMO DE 10 PIES 3 METROS NIVEL DE AGUA DE BOMBEO UNA EL CABLE CON UNA CINTA CADA 3 METROS MÍNIMO DE 5 PIES 1 5 METROS VERIFIQUE LA VÁLVULA CADA 200 METROS CABLE DE SEGURIDAD Proceso C paso 1 único Descenso de la bomba Descenso de la bomba A Instalación típica de una bomba sumergible para pozos con adaptador hori...

Page 33: ...uro de polivinilo como sea necesario para conectar el adaptador macho de cloruro de polivinilo de 1 pulgada en la válvula de compuerta al adaptador macho de cloruro de polivinilo de 1 pulgada en la ensambladura de ranura horizontal La instalación completa deberá parecerse al dibujo de la página siguiente CHO E POLIVINILO INTERRUPTOR DE PRESIÓN RPS BOQUILLA DE 1 4 DE PULGADA X 3 PULGADAS MANÓMETRO ...

Page 34: ...s internas del interruptor de presión números 2 y 3 Instale los conductores desde las dos terminales exteriores del interruptor de presión líneas 1 y 4 hasta el suministro eléctrico o a la caja de fusibles Instale un conductor desde el tornillo de conexión a tierra hasta la barra de conexión a tierra de la caja de fusibles Véase la tabla a seguir para las especificaciones mínimas de servicio de la...

Page 35: ...ÓN A TIERRA DE LA CASA CONDUCTOR DE CONEXIÓN A TIERRA VERDE NEGRO POTENCIA DISYUNTOR DEL CIRCUITO PRINCIPAL BARRAS COLECTORAS CONDUCTORES DE SUMINISTRO ELÉCTRICO DE LA EMPRESA PROVEEDORA DE SERVICIO ELÉCTRICO NORMALMENTE SON NEGROS BARRA NEUTRA LOS CONDUCTORES BLANCOS SÓLO SE USAN CONEXIÓN A TIERRA DE LA CASA CONDUCTOR DE CONEXIÓN A TIERRA VERDE NEGRO POTENCIA DISYUNTOR DEL CIRCUITO PRINCIPAL BARR...

Page 36: ...ía no ser aplicable en su caso Esta garantía le da derechos legales específicos y podría tener también otros derechos los cuales variarán de estado a estado En caso de ausencia de comprobante adecuado de la fecha de compra la fecha efectiva de esta garantía se basará en la fecha de fabricación Enviar todas las notificaciones etc a Product Warranty and Return Dept Water Ace Pump Co 1101 Myers Parkw...

Reviews: