4.2 Numeric and Character Indications 

 

Indications on the main display and characters correspond to them are 

as below: 

 

0  1  2  3  4  5  6  7  8  9  -  / 

A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R 

R  S  T  U  V  W  X  Y  Z 

 

4.3

 

Parameter Types and Protect Levels 

The parameters are classified into the following groups depending on 
the  main  objective.  Use  of  the  protect  setting  in  the  condition  data 
allows a limitation to be imposed on the settable parameters. 

 

Condition data:

 

A  group  of  parameters  that  set  up  basic  actions 
such  as the sampling rate  and  operation type for 
each control. 

 

Scaling data:

 

A  group  of  parameters  relating  to  measurements 
such as scaling.

 

Linearize data:

 

A  group  of  parameters  relating  to  the  function  of 
correcting  the  linearity  of  an  input  value  and 
display value.

 

 
 
 

4.4

 

Shift to the Parameter Setting Mode 

 

 

measuremant operation 

Condition data 
 

E 

M 

 

 

 

M 

M 

M 

M 

M 

M 

M 

M 

M 

Scaling data 
 

Linearize data 

E 

By pressing the Enter key, new parameters are stored and returns to measuremant 

operation. 

M 

 

 
 
 

4.5 Protect Levels 

 

Protect level 0 (PL0):  Allows  all  parameters  to  be  displayed  and 

set. 

Protect level 1 (PL1):  Allows  condition  data 

*1

  and  scaling  data  to 

be displayed and set. 
(*1)  Protect  level,  range,  averaging  times 
(setting sampling) and BCD output type only. 

Protect  level  2  or  3 
(PL2, 3): 

Allows only protect level in condition data to 
be displayed and set. 

 
 
 

 

 

 
 
 
 
 
 
 
 
 

 
4.6

 

 

Setting Condition Data 

Condition data is a group of parameters for setting up basic actions such 
as  a  protect  level,  measurement  range,  and  each  con

trol’s  operation 

type. 

 

 

 
(1)  Press  the  Enter key  and  the  Mode key  during  measurement 
operation to enter the condition data setting mode. 
 
 
(2)

 

Press the Mode key to move to protect level setting. 

 
 
(3) Press the Mode key to display the current protect level. 
 
 
 
(4) Set up the desired protect level using the Increment key. 
(This setting example sets the protect level to PL1.) 

PL0: Displays all the parameters.   
PL1: Displays only the condition and scaling data.   
PL2/3:    Displays only the protect level.   

   

 

* Press the Mode key to skip the setting of this item. 

 
 
 
(5) Press the Mode key to move to peak-hold-type setting. 
 
 
(6) Set up the peak hold type using the Increment key. 
(This setting example sets peak hold type to PH.) 
        PH:   

Holds the maximum display value.   

        PV:   

Holds the minimum display value.   

        PVH:   

Displays (holds) the difference between the 

 

                 

maximum

 

and minimum values.   

* Press the Mode key to skip the setting of this item. 

 
 
(7) Press the Mode key to move to range setting. 
 
 
(8) Set the range using the Increment key. 
(This setting example sets input range to 14) 

11 : 

±

199.99mV 

 

    13: 

±

19.999V 

12 : 

±

1.9999V 

 

      14: 

±

199.99V 

22 : 

±

1.9999mA 

 

    23: 

±

19.999mA 

24 : 

±

199.99mA 

 

    25: 

±

1999.9mA 

* Press the Mode key to skip the setting of this item. 
 
(9) Press the Mode key to move to averaging count setting. 
 
(10) Set the number of averaging times using the Increment key.   

1: Single (No averaging) (approx. 25 times/sec)   
2: Twice averaging (approx. 12.5 times/sec)   
4: Four-time averaging (approx. 6.25 times/sec)   
8: Eight-time averaging (approx. 3.125 times/sec)   
10: Ten-time averaging (approx. 2.5 times/sec)   
20: Twenty-time averaging (approx. 1.25 times/sec)   
40: Forty-time averaging (approx. 0.625 time/sec)   
80: Eighty-time averaging (approx. 0.31 time/sec)   
100: Hundred-time averaging (approx. 0.25 time/sec)   
200: Two hundred-time averaging (approx. 0.13 time/sec) 
* Press the Mode key to skip the setting of this item. 

 
(11) Press the Mode key to move to moving averaging count 
setting. 
(12)  Set  the  number  of  moving  averaging  times  using  the 
Increment 

key.   

OFF: No moving averaging      8: 8 times 
2: Twice                                  16: 16 times 
4: 4 times                                32: 32 times 

* Press the Mode key to skip the setting of this item. 

(13) Press the Mode key to move to step-wide setting. 
 
(14) Set up step-wide using the Increment key.   

1: Normal display   
2: Only even numbers in the least significant digit   
5: Only "0" or "5" in the least significant digit   
0: Only "0" in the least significant digit   

* Press the Mode key to skip the setting of this item. 

(15) Press the Mode key to move to display blank setting. 
 
 
(16) Set up display blank using the Increment key.   
 

OFF: Normal brightness condition (brightest)   

 

b-3: Bright   

 

b-2: Slightly dim   

 

b-1: Dim   

                ON: display lights off 

      * Press the Mode key to skip the setting of this item. 
 

(17) Press the Mode key to move to digital limiter type setting. 

 

E 

M 

M 

▲ 

(  M  ) 

M 

M 

M 

(  M  ) 

Approx. 1sec 

M 

M 

(  M  ) 

(  M  ) 

M 

(  M  ) 

(  M  ) 

M 

M 

Measurement operation 

Approx. 1sec 

Approx. 1sec 

Approx. 1sec 

Approx. 1sec 

Summary of Contents for A9000 Series

Page 1: ...12 22 or 23 range Input terminal HI input terminal of 13 or 14 24 or 25 range Input terminal LO input terminal Selecting input range can not be done only by connecting input signal to a suitable termi...

Page 2: ...vel 3 5 5V Input current 0 5mA 4 Parameter Settings 4 1 Components and Functions Before setting parameters remove the front panel by inserting a flat blade screwdriver into the ditch under the front p...

Page 3: ...item 5 Press the Mode key to move to peak hold type setting 6 Set up the peak hold type using the Increment key This setting example sets peak hold type to PH PH Holds the maximum display value PV Ho...

Page 4: ...Enter and Mode keys during measurement operation to enter the condition data setting mode 2 Press the Shift key to move to the scaling data setting mode 3 Press the Mode key to display the number of...

Page 5: ...the setting again The number of linearize points is up to 16 but a value 17 to 19 is also displayed during setup Note that if you set a value from 17 to 19 it is forced to set to 16 5 Other Functions...

Page 6: ...23 19 999mA 24 199 99mA 0 1 3A 25 1999 9mA Common specifications A D conversion conversion method Input circuit Single ended Setting sampling rate 25times sec max Overrange warning For an input signa...

Page 7: ...ble ON disable OFF of the linearize function and data clear CLR TR T Tracking zero correction time 00 PL0 00 99 Sets the correction time of the tracking zero function Every TR T setting sampling perio...

Page 8: ...period 1 25 times sec 40ms 20 1 25 times sec 800ms 2 12 5 times sec 80ms 40 0 625 times sec 1 6s 4 6 25 times sec 160ms 80 0 3125 times sec 3 2s 8 3 125 times sec 320ms 100 0 25 times sec 4s 10 2 5 ti...

Reviews: